ADG-L Series Programmable DC Power Supply
108
Parameter
Start address
(hex)
Byte count
Data type
Unit
Precision
Output setting
01 18
1
Control flag
-
-
Bit-7
Reserved
Bit-6
Reserved
Bit-5
Reserved
Bit-4
Reserved
Bit-3
Reserved
Bit-2
Reserved
Bit-1
Reserved
Bit-0
1
:
Start output
0
:
Stop output
Function code available
:
03
、
10
The control authority (start address 01 38) should be set to 01 (remote control
mode) for writing permission.
Example
:
Given the slave ID is 01 and to set the output to ON
Send: 01 10 01 01 18 01 5B F5
Receive: 01 10 00 00 00 1D
Given the slave ID is 01 and to set the output to OFF
Send: 01 10 01 01 18 00 9A 35
Receive: 01 10 00 00 00 1D