ADG-L Series Programmable DC Power Supply
110
Parameter
Start address
(hex)
Byte count
Data type
Unit
Precision
Reset
01 2D
1
Control flag
-
-
Bit-7
Reserved
Bit-6
Reserved
Bit-5
Reserved
Bit-4
Reserved
Bit-3
Reserved
Bit-2
Reserved
Bit-1
Reserved
Bit-0
1
:
Reset
Function code available
:
10
The control authority (start address 01 38) should be set to 01 (remote control
mode) for writing permission.
Example
:
Given the slave ID is 01 and reset the output
Send: 01 10 01 01 2D 01 4C A5
Receive: 01 10 00 00 00 1D