Preen ADG-L Series Скачать руководство пользователя страница 1

 
 

 

 

ADG-L Series 

(5kW/10kW/15kW)

 

Programmable DC Power Supply 

User Manual 
 
 
 
 

AC Power Corp. (Preen) 

 

V 1.04.00 EN 

The information in the document is subject to change without notice. 

Copyright 2022 AC Power Corp. (Preen). All roghts reserved.

Содержание ADG-L Series

Страница 1: ...5kW 10kW 15kW Programmable DC Power Supply User Manual AC Power Corp Preen V 1 04 00 EN The information in the document is subject to change without notice Copyright 2022 AC Power Corp Preen All rogh...

Страница 2: ...for a particular purpose AC Power Corp shall not be held liable for errors contained herein or direct indirect special incidental or consequen tial damages in connection with the furnishing performan...

Страница 3: ...cost Preen assumes no responsibility for its product being used in a hazardous or dan gerous manner either alone or in conjunction with other equipment High volt age used in some products may be dang...

Страница 4: ...e quire ments 1 BEFORE APPLYING POWER Verify that the equipment is set to match with the power line input 2 PROTECTIVE GROUND Make sure to connect the equipment to the protective ground to prevent an...

Страница 5: ...Component replacement and internal adjustment can be done only by qualified service per sonnel Warning LETHAL VOLTAGES The equipment can supply 1000V peak at its output DEATH on contact may result if...

Страница 6: ...ALUE 17 2 3 2 WIRE SELECTION 18 2 4 INPUT CONNECTION 22 2 5 OUTPUT CONNECTION 23 2 6 REMOTE SENSE CONNECTION 24 2 7 FUNCTION DIP SWITCH 27 2 8 ANALOG CONNECTION 28 2 9 RS 232 RS 485 INTERFACE CONNECTI...

Страница 7: ...6 2 GPIB INTERFACE BOARD OPTION 68 3 6 3 ETHERNET RS 485 RS 232 USB INTERFACE BOARD OPTION 68 3 7 WAVE PAGE 70 3 8 EVENT PAGE 72 3 9 INFORMATION PAGE 73 3 10 PROGRAMMABLE PGM FUNCTION 75 3 10 1 PGM PA...

Страница 8: ...REGISTER ERROR 99 5 4 3 WRITE REGISTER CORRECT 100 5 4 4 WRITE REGISTER EOORO 101 5 5 MODBUS ADDRESS LIST 102 5 5 1 READ ONLY SECTION 102 5 5 2 READ WRITE SECTION 107 5 5 3 ADVANCED SECTION 112 6 CALI...

Страница 9: ...lished selectively via the standard interfaces R S 232 RS 485 Modbus and Analog or the optional interfaces Ethernet USB R S 232 RS 485 Modbus SCPI or GPIB The model naming rule of ADG L series Output...

Страница 10: ...RS 232 RS 485 Ethernet USB or GPIB 3 Remote control via analog interface 4 Protection for OVP OCP OPP OTP Line OVP Vin LVP Vin OVP Phase loss and Fan Error B Input Output 1 Universal input voltage ran...

Страница 11: ...35V 0 335V Current 0 45A 0 32A 0 15A 0 45A CV mode Voltage ripple rms 0 25 F S 0 2 F S 0 08 F S 0 08 F S Voltage noice p p 1 6 F S 1 6 F S 0 8 F S 0 8 F S Voltage line regulation 0 1 F S 0 1 F S 0 1 F...

Страница 12: ...40 C Storage temperature 20 C 70 C Protection OVP OCP OPP OTP Vin OV Vin Unbalance LDC OV OVP range 0 110 F S OCP range 0 110 F S Dimension HxWxD 132 x 442 x 692 mm Weight 5kW approx 19 1kg 1 The load...

Страница 13: ...3 F S 0 15 F S 0 15 F S 0 08 F S 0 08 F S 0 08 F S Voltage noice p p 2 5 F S 2 5 F S 1 6 F S 1 6 F S 0 8 F S 0 8 F S 0 8 F S Voltage line regulation 0 1 F S 0 1 F S 0 1 F S 0 1 F S 0 03 F S 0 03 F S...

Страница 14: ...n 10mA Power programming accuracy 0 4 F S Power measure ment accuracy 0 4 F S Power resolution 0 01kW General specs Efficiency 90 at max power Interfaces Standard RS 485 RS 232 Modbus Analog Option Et...

Страница 15: ...A 0 30A 0 23A 0 15A 0 45A CV mode Voltage ripple rms 0 3 F S 0 3 F S 0 15 F S 0 15 F S 0 15 F S 0 15 F S 0 1 F S 0 1 F S Voltage noise p p 1 6 F S 1 6 F S 1 F S 1 F S 0 8 F S 0 8 F S 0 5 F S 0 5 F S V...

Страница 16: ...0 08 F S 100mV Voltage measure ment accurecy 0 08 F S 100mV Voltage resolution 100mV Current program ming accuracy 0 4 F S 60mA Current measure ment accuracy 0 4 F S 60mA Current resolution 10mA Powe...

Страница 17: ...rated input voltage 2 Meaning the time that require for output voltage to change from 10 to 90 or 90 to 10 at full scale 3 Meaning the time that require for output voltage to return to 1 of the set vo...

Страница 18: ...ADG L Series Programmable DC Power Supply 10 1 4 Exterior ADG L series exterior is as below a Front side of ADG L with handles b Right side of ADG L with handles...

Страница 19: ...ADG L Series Programmable DC Power Supply 11 With cover c Rear side of ADG L Figure 1 2 Outline drawings of the ADG L series Figure 1 3 Outline drawing of the ADG L series...

Страница 20: ...ngs and read meas urements The touch screen can be operated with a finger or with a stylus 3 Rotary Knob To set parameters configure settings and read meas urements Push the knob to confirm the select...

Страница 21: ...ble by Preen s personnel 9 S1 RS 485 RS 232 Interface switch Used to select between RS 232 and RS 485 interface Notice Please switch to RS 232 if using external commu nication board 10 S2 RS 485 termi...

Страница 22: ...cable so please con tact us for the connecting cable if multi machine ap plication is needed 2 Use while the external analog control is needed 3 Two sets to provide expandable application to control...

Страница 23: ...ed within 40 C 2 2 1 Notice for Installation 1 The device must be installed on horizontal grounds and should be located near the load so that the connection is as short as possible 2 Leave sufficient...

Страница 24: ...ADG L Series Programmable DC Power Supply 16 Figure 2 1 The required space for the device...

Страница 25: ...type Input frequency 47 63 Hz Maximum current refer the section 1 3 for the maximum inpur current of each model Figure2 2 The product label Caution Please ensure the input voltage which is strongly re...

Страница 26: ...2 38mm 2 ADG L 160 32 30A 5 5mm 2 5 5mm 2 5 5mm 2 ADG L 160 63 60A 14mm 2 14mm 2 14mm 2 ADG L 160 94 90A 38mm 2 38mm 2 38mm 2 ADG L 335 15 30A 5 5mm 2 5 5mm 2 5 5mm 2 ADG L 335 45 15 30A 5 5mm 2 5 5m...

Страница 27: ...19A 3 5 5mm 2 3 Y 3 5mm 2 3 5 5mm 2 3 Y 3 5mm 2 3 5 5mm 2 3 Y 3 5mm 2 ADG L 335 45 3 52A 3 Y 30A 3 14mm 2 3 Y 5 5mm 2 3 14mm 2 3 Y 5 5mm 2 3 14mm 2 3 Y 5 5mm 2 ADG L 335 135 15 3 52A 3 Y 30A 3 14mm 2...

Страница 28: ...2 ADG L 160 32 160V 32A 5 5 mm 2 5 5 mm 2 ADG L 160 63 160V 63A 22 mm 2 22 mm 2 ADG L 160 94 160V 94A 38 mm 2 38 mm 2 ADG L 335 15 335V 15A 2 0 mm 2 2 0 mm 2 ADG L 335 45 15 335V 45A 14mm 2 14 mm 2 AD...

Страница 29: ...emperature below 35 temperature rating of conductor isulation 60 Table 2 3Current rating of AWG Notice The tables above give minimum recommended wire size these recommendations are for multi core flex...

Страница 30: ...panel 2 Connect the power cables firmly to the input terminals Connection configu rations differ from models single three phase input and input voltage Shorting links are attached for different connec...

Страница 31: ...efer to Figure 1 5 Connect and of the output terminals to the load For safety the safety cover for the output terminals must be fastened after each output connection The wires to the load must have su...

Страница 32: ...d S of the remote sense connector to the corresponding terminals at the load The sensing leads are for voltage monitoring feed back of the device so they must have a low resistance in order to maintai...

Страница 33: ...connection this is an example of two units in serial For more DB25 information please refer to section 2 8 c Remote sensing connection parallel connection example of two units in parallel For more DB2...

Страница 34: ...burn out c If the sensing leads are connected with reverse polarity the CC mode will be activated and the sensing leads could burn out d If the sensing leads are connected correctly but the connection...

Страница 35: ...r switch The resistance value to be The resistance value to be 120 S3 Series and parallel switch Series Parallel S4 CANBUSterminal resistor switch The resistance value to be The resistance value to be...

Страница 36: ...on speed 250kb s or communication distance 300m d S4 switch to the right the CANBUS terminal resistor switches to ON for transmis sion speed 250kb s or communication distance 300m Figure 2 8 S3 and S4...

Страница 37: ...programming of the overcurrent protection 0 5 Vdc 0 102 of full scale output current 15 PS ON Input Control signal for the device ON OFF a logic high state 5V is to turn ON the device a logic low stat...

Страница 38: ...ADG L 160 32 ADG L 335 15 ADG L 335 45 5 ADG L 115 90 ADG L 160 63 ADG L 335 30 ADG L 335 90 10 ADG L 500 20 ADG L 670 15 ADG L 670 45 10 ADG L 115 135 ADG L 160 94 ADG L 335 45 ADG L 335 135 15 ADG L...

Страница 39: ...ansmission speed 250kb s or communication distance 300m d S2 switch to the right the RS 485 terminal resistor switches to ON used when transmission speed 250kb s or communication distance 300m Figure...

Страница 40: ...ommended Different colors of cables are recommended for identi fication Please only have single ground connected Single ground menas there is only one ground in communication circuit Avoid T connectio...

Страница 41: ...01 10 00 00 00 1D The touch screen HMI of the device will show local operation 7 To switch the device to remote operation The PC sends 01 10 01 01 38 01 42 35 The device ADG L replies 01 10 00 00 00...

Страница 42: ...PI In order to control the unit remotely via RS 232 or RS 485 please connect to the computer by D9 connector The pin description is below Figure 2 12 RS232 RS485 D9 pin Pin Description 1 No Connection...

Страница 43: ...maximum current up to 300mA It can be used as a power supply for analog control device or circuit Figure 2 13Accessory power outlet 2 12 USB Interface for firmware update only The standard USB interf...

Страница 44: ...tective ground could cause a potential shock hazard that result in personal injury Apply power and press the power switch to turn on the device then the touch screen on the front panel will light up a...

Страница 45: ...s Programmable DC Power Supply 37 2 14 Handles Installation Install the handles to the right side and the left side of the device with eight screws please refer to Fifure 2 17 Fifure 2 17 Installing t...

Страница 46: ...and install the external interface card referring to Then fix the screws to complete the installation Please refer to Figure 2 18 Figure 2 18 External interface card installation Notice The optional i...

Страница 47: ...f touch screen represents an operational page Before the description of each operational page the following shows how to use touch screen and rotary knob to input programming data or options When the...

Страница 48: ...knob on the front panel to move the cursor on the screen and press the rotary knob to select item Once the item is selected turn the rotary knob to ad just the numeric value or set the parameter valu...

Страница 49: ...the meas ure ment readings of the device output Users can set output value by using the touch screen or the rotary knob refer to Section 3 2 and then press the Output Reset Button on the front panel...

Страница 50: ...E page 8 Press to enter into the WAVE page refer to section3 7 9 Show the status of the device or the error code 10 Press to lock unlock the touch screen If an attempt is made for alteration whilst th...

Страница 51: ...set current value in in the meantime to make sure outpur correctly For more information please refer to section 3 3 2 3 3 2 Constant current CC mode setting Press the item CURRENT at the MAIN page to...

Страница 52: ...tant power CP mode The power range varies according to the models refer to Section 1 3 Below is an example of model ADG L 335 135 15 of which the output power ranges from 0 00kW 15 31kW The product s...

Страница 53: ...er into the PGM page refer to Section 3 10 3 Press to enter into the COMMUNICATION page refer to Section 3 6 4 Press to enter into the EVENT page refer to Section 3 8 5 Press to enter into the WAVE pa...

Страница 54: ...ollowing figure Figure 3 10 SETTINGS page The descriptions for the items and the icons at the SETTINGS page are given as fol lows 1 Press to enter into SYSTEM page 2 Press to enter into PROTECTION pag...

Страница 55: ...e backlight level of the touch screen with options from 1 to 9 2 Press to set the language ENGLISH tra ditional Chinese simplified Chinese 3 Press to enable disable the key sound 4 Press to enable dis...

Страница 56: ...2 8 Press to set the date 1 31 9 Press to set the hour 0 24 10 Press to set the minute 0 60 11 Press to set the second 0 60 12 Press to move to the previous page of the SYSTEM 13 Press to move to the...

Страница 57: ...he screen will be Figure 3 12 Set the backlight level from 8 to 5 The procedures of setting the backlight level for example from 8 to 5 by using the touch screen are given as below 1 Press the item re...

Страница 58: ...peatedly to select the desired language 2 Press the icon to confirm 3 5 1 3 Key Sound Users can set the key sound via the touch screen or the rotary knob refer to Section 3 2 Key sound has two options...

Страница 59: ...ADG L Series Programmable DC Power Supply 51 The procedures of setting the key sound are given as below 1 Press the item to switch the key sound 2 Press the icon to confirm...

Страница 60: ...To change the password please enter the current password Enter 0000 to disable the function Figure 3 15 Screen lock password setting Notice If the user forget the password and would like to unlock th...

Страница 61: ...ally according to the time setting The time to lock is based on the idle time of the touch screen Figure 3 16 Automatic screen lock setting 3 5 1 6 Date and Time Setting Users are allowed to set date...

Страница 62: ...ADG L Series Programmable DC Power Supply 54 4 Follow the above procedures to complete the date and time setting Figure 3 18 Month Hour Minute Second setting...

Страница 63: ...le Figure 3 19 Protectionsetting The descriptions for the items and the icons at the PROTECTION page are given as follows 1 Press to set the overvoltage protection point protec tion range 0 0 rated 11...

Страница 64: ...vice generates an output voltage higher than the set point of OVP the OVP will be triggered the device output will be switched off immediately and shows OVP the Output Reset Button will turn red Figur...

Страница 65: ...the device generates an output current higher than the set point of OCP the OCP will be triggered the device output will be switched off and shows OCP the Output Reset Button will turn red Figure 3 21...

Страница 66: ...he device generates an output power higher than the set point of OPP the OPP will be triggered the device output will be switched off and shows OPP the Output Reset Button will turn red Figure 3 22 OP...

Страница 67: ...e phase three phase three wires When input voltage 468V signle phase three phase four wires for at least 1 second Vin Unbalance Input overvoltage 1 The difference of a power module s input voltage bet...

Страница 68: ...nt x 1 1 Parallel operation MS_OCP level rated output current x 1 1 x number of the unit MS OPP MS mode over power protection In MS mode the total output power MS_OPP level Series operation MS_OPP lev...

Страница 69: ...Page Press the icon to enter into DIAGNOSIS page please refer to the following figure The DIAGNOSIS page records the error information Please report the infor mation at the DIAGNOSIS page to Preen s...

Страница 70: ...ions for the items at the ADVANCED page are given as follows 1 Press to select the voltage resolution to 1V or 0 1V 2 Press to select group type 3 Press to enter calibration page refer to section 6 4...

Страница 71: ...re fer to Section 3 2 There are four types Mode 1 Group 25 Step 16 Mode 2 Group 10 Step 40 Mode 3 Group 5 Step 80 Mode 4 Group 2 Step 200 Users can select the most suitable group type mode base on th...

Страница 72: ...ed resolution the resolution is fixed Figure 3 26 Encoder mode page 3 5 4 2 Voltage Slew Rate V mS User can set up the voltage slew rate by touch screen or rotary knob The slew rate may be different a...

Страница 73: ...3 Current Slew Rate A mS User can set up the current slew rate by touch screen or rotary knob The slew rate may be different according to different models When set to OFF the default is to set the fa...

Страница 74: ...o adjust the actual slew rate for customer de sired application a Setting voltage slew rate in order to get the actual voltage output slew rate fix the current slew rate as default to adjust the value...

Страница 75: ...LOCAL REMOTE and ANALOG Please refer to the figures below Figure 3 29 CONTROL MODE setting The descriptions for the items and the icons at the CONTROL MODE page are given as follows 1 Press to set to...

Страница 76: ...the setting page Please refer to the figures below Figure 3 30 GPIB board setting 3 6 3 Ethernet RS 485 RS 232 USB Interface Board option When the optional Ethernet RS 485 RS 232 USB interface board i...

Страница 77: ...ADG L Series Programmable DC Power Supply 69 Figure 3 32 Ethernet setting Figure 3 33 RS 232 RS 485 USB setting...

Страница 78: ...3 34 Figure 3 34 The icons to enter into WAVE page at MAIN and MENU page The procedures of entering WAVE page are given as below 1 At the MAIN page press the icon to enter into the WAVE page 2 At the...

Страница 79: ...2V 10V 40V 100V 300V 4 Press to switch current per division between 2A 20A 60A 5 Press to switch power per division between 500W 1kW 5kW 10kW Notice The waveform shown in the WAVE page is generated by...

Страница 80: ...Power Supply 72 3 8 EVENT Page Press the icon at the MENU page to enter into the EVENT page The EVENT page records the error information including date time and error codes Please refer to the figure...

Страница 81: ...TION page The descriptions for the items and the icons at the INFORMATION page are given as follows 1 The manufacturer of the product 2 The model of the product 3 The serial number of the product 4 Th...

Страница 82: ...r Supply 74 8 The version of the human machine interface HMI firmware 9 The version of the hardware of the device 10 Press to move to the previous page of the INFORMATION page 11 Press to move to the...

Страница 83: ...2 to program the output ac cording to the set values in each STEP 3 10 1 PGM Page Figure 3 39 The icons to enter into PGM page at MAIN and MENU page The procedures of entering PGM page are given as be...

Страница 84: ...GE to change to different pages and the touch screen will display 3 steps at once 5 Press GROUP to select the request group or change the GROUP name For detail information please refer to 3 10 2 GROUP...

Страница 85: ...settings Section 3 5 4 3 to simulate different test sequences For example when the starting STEP of a loop is number 1 the ending STEP of a loop is 6 and the STEP loop times is 5 the device will seque...

Страница 86: ...PGM page when the PGM function is active is given as follows 1 shows the number of the starting STEP 2 shows the number of the ending STEP 3 shows the STEP loop time The numerator indicates the curren...

Страница 87: ...example if the time is set to 10 seconds this item will be shown as 10s 9s 8s 2s 1s 0s 3 10 4 Example of STEPs for simulataion To illustrate the simulation feature through STEPs the figures shown bel...

Страница 88: ...ER B Setting the SLAVE 3 11 1 MULTI MACH Setting Figure 3 45 Multi Mach Setting Page The procedures of entering MULTI MACH page are given as below refer to Figure 3 45 Notice The master unit and the s...

Страница 89: ...scription for the items at the MULTI MACH page is given as follows refer to Figure 3 46 1 Press to activate multiple machie MULTI MACH func tion settings 2 Press to set the unit as MASTER or SLAVE 3 P...

Страница 90: ...op the multi machine function and MS mode Users have to set the Mul ti Machine function to START to activate the MS mode when settings are edit ed Messages indicating success of connection will show a...

Страница 91: ...E will appear at the MAIN page Press the icon to enter into the page viewing the information of the connecting units For example the MASTER unit is with CAN ID 127 the SLAVE unit is with CAN ID 1 Refe...

Страница 92: ...ed remotely via RS 232 RS 485 MODBUS and optional interfaces RS 232 RS 485 MODBUS SCPI Ethernet USB or GPIB Additionally ADG L series provides the control software Preen Program that allows users to e...

Страница 93: ...anguage Make sure these settings identical with the device s setting before communication refer to section 3 6 4 Connect the communication cable to the computer RS 232 RS 485 USB Find the COM port num...

Страница 94: ...4 3 COM port Figure 4 4 Select serial COM port in Preen Program 5 Click and choose to test whether the communication between power supply and PC is well connected The figures below show the control so...

Страница 95: ...n between the device and a PC click EXIT to exit the communication test page Confirm the settings in the system setup page refer to figure Figure 4 2 to exit Choose in the the start up page refer to F...

Страница 96: ...mode 2 Use to set the output current in CC mode 3 Use to set the output power in CP mode 4 Click to turn on the output Refer to Figure 4 8 5 Click to turn off the output 6 Show the output voltage val...

Страница 97: ...ADG L Series Programmable DC Power Supply 89 Figure 4 9 Figure 4 10 Figure 4 8 The GENERAL mode when the output turns on Figure 4 9 Select to generate the report in TXT or CSV format...

Страница 98: ...ADG L Series Programmable DC Power Supply 90 Figure 4 10 Export report CSV and TXT format...

Страница 99: ...gure 4 11 Regarding to the operation in Preen Program please refer to section 3 10 1 Click Program Mode to set the STEPs 2 Click to set the output voltage for CV mode current for CC mode power for CP...

Страница 100: ...to as slave it will not allow data exchange between slave devices Therefore terminal devices will not engage the communication link at initialization but only respond to the master s request 5 1 Tran...

Страница 101: ...s decimal value range is 0 255 A master addresses a slave by placing the slave ID in the ID field of the message When the slave sends its response it places its own ID in this ID field of the response...

Страница 102: ...RC16 calculation 1 CRC calculation is first started by preloading the whole 16 bit register to1 s 2 The process begins by applying successive 8 bit bytes of the message to the current contents of the...

Страница 103: ...n code not 03 hex or 10 hex 04 Start address incorrect 05 The value of register data to write is beyond the range 06 The slave is at LOCAL operation the master is not allowed to write 07 The frame len...

Страница 104: ...l value General fraction 4 bytes Integer part Fractional part Data0 Data1 Data2 Data3 1 byte 1 byte 1 byte 1 byte Range 0 255 Range 0 99 Range 0 99 Range 0 99 General fraction represents a value from...

Страница 105: ...ta0 Data1 Data2 Data3 1 byte 1 byte 1 byte 1 byte Range 0 255 Range 0 99 Range 0 99 Range 0 99 High fraction represents a value from 0 to 255 999999 with 4 bytes Formula value Data0 Data1 100 Data2 10...

Страница 106: ...ut voltage Start address lo 00 The start address of the output voltage CRC check lo 58 T he CRC value after calculating 01 03 04 00 00 hex CRC check hi 45 T he CRC value after calculating 01 03 04 00...

Страница 107: ...address of the output voltage hi Start address lo 00 The start address of the output voltage lo CRC check lo 58 The CRC value after checking 01 03 04 00 00 hex lo CRC check hi 00 The CRC value after c...

Страница 108: ...r data type of Iset is general fraction Convert the Iset 15 54A into the register data 00 0F 36 00 hex Data 0F Data 36 Data 00 CRC check lo 94 The CRC value lo after checking 01 10 04 01 04 00 0F 36 0...

Страница 109: ...ta 00 The register data type of Iset is general fraction Convert the Iset 15 54A into the register data 00 0F 36 00 hex Data 0F Data 36 Data 00 CRC check lo 94 The CRC value lo after checking 01 10 04...

Страница 110: ...fraction V 0 1 Iout 00 04 4 General fraction A 0 01 Pout 00 08 4 General fraction kW 0 01 Function code available 03 Example Given the slave ID is 01 and Vout is 88 4V Send 01 03 04 00 00 58 45 Recei...

Страница 111: ...de Bit 0 1 Output at CV mode Function code available 03 Example Given the slave ID is 01 and output is at CV mode Send 01 03 01 00 18 48 4E Receive 01 03 00 01 09 D8 12 Given the slave ID is 01 and ou...

Страница 112: ...Vin Unbalance Unbalance input voltage Bit 5 Vin OV Over input voltage Bit 4 Vin UV Insuffiecient input voltage Bit 3 OPP Over power protection Bit 2 OTP Over temperature protection Bit 1 OCP Over cur...

Страница 113: ...memory data error Bit 6 Hardware over current protection Bit 5 Hardware over voltage protection Bit 4 Hardware over power protection Bit 3 Reserved Bit 2 FAN Error Bit 1 Reserved Bit 0 Programmable p...

Страница 114: ...normal sta tus 03 00 1B 1 Status Bit 7 Reserved Bit 6 DC over line voltage Bit 5 Reserved Bit 4 Reserved Bit 3 Reserved Bit 2 EEPROM Error Bit 1 DC Bus Error Bit 0 Phase Loss Function code available 0...

Страница 115: ...03 10 The control authority start address 01 38 should be set to 01 remote control mode for writing permission Example Given the slave ID is 01 and write the Vset 66 4V Send 01 10 04 01 00 00 42 04 0...

Страница 116: ...t 2 Reserved Bit 1 Reserved Bit 0 1 Start output 0 Stop output Function code available 03 10 The control authority start address 01 38 should be set to 01 remote control mode for writing permission Ex...

Страница 117: ...The control authority start address 01 38 should be set to 01 remote control mode for writing permission Example Given the slave ID is 01 and write the OVP point 340V Send 01 10 04 01 21 03 28 00 00...

Страница 118: ...ved Bit 6 Reserved Bit 5 Reserved Bit 4 Reserved Bit 3 Reserved Bit 2 Reserved Bit 1 Reserved Bit 0 1 Reset Function code available 10 The control authority start address 01 38 should be set to 01 rem...

Страница 119: ...8 1 Control code 00 Local control 01 Remote control 02 Analog control Function code available 03 10 Example Given the slave ID is 01 and to set to the local control Send 01 10 01 01 38 00 83 F5 Receiv...

Страница 120: ...eral fraction A 0 01 Pset MAX 08 48 4 General fraction kW 0 01 Pset MIN 08 4C 4 General fraction kW 0 01 Function code available 03 Example Given the slave ID is 01 and Vset MAX is 330 1V Send 01 03 0...

Страница 121: ...X 08 89 4 General fraction kW 0 01 Function code available 03 Example Given the slave ID is 01 and OVP MAX is 400V Send 01 03 04 08 79 9E 67 Receive 01 03 00 04 04 00 00 00 42 37 Given the slave ID is...

Страница 122: ...oltmeter open crcuit Ammeter short circuit Figure 6 1 Meter connection To enter the Calibration page press Settings at MENU page press Advanced at Set ting page press Calibration at Advanced page and...

Страница 123: ...t Voltage Accuracy Calibration page 2 Press to enter Output Voltage Indicated Value and Set Value Calibration 3 Press to enter Output Current Accuracy Calibration page 4 Press to enter Output Current...

Страница 124: ...the voltmeter and the output is open circuit Please refer to Figure 6 5 4 Press Output Reset Button to output Stage 1 low voltage point Please refer to Figure 6 6 5 When READ VALUE 1 is stabilized ent...

Страница 125: ...ADG L Series Programmable DC Power Supply 117 Figure 6 5 Output voltage accuracy calibration Figure 6 6 Process to output voltage accuracy calibration page...

Страница 126: ...Stage 1 low voltage point at V set PROMPT product output is open circuit 3 Press Output Reset Button to output Stage 1 low voltage point Please refer to Figure 6 9 4 When READ VALUE 1 is stabilized pr...

Страница 127: ...ADG L Series Programmable DC Power Supply 119 Figure 6 9 Process to output reading voltage and setting voltage...

Страница 128: ...Figure 6 12 Connect the voltage meter to output open circuit 4 Press Output Reset Button to output Stage 1 low voltage point Please refer to Figure 6 13 5 When READ VALUE 1 is stabilized enter the val...

Страница 129: ...eries Programmable DC Power Supply 121 Figure 6 11Connection to remote voltage compensation calibration Figure 6 12 Remote voltage compensation page Figre 6 13 Running remote voltage compensation cali...

Страница 130: ...output is short circuit 4 Press Output Reset Button to output Stage 1 low current point Please refer to Figure 6 16 5 When READ VALUE 1 is stabilized enter the measured value of ammeter in INPUT 1 6 P...

Страница 131: ...ADG L Series Programmable DC Power Supply 123 Figure 6 15 Output current calibration page Figure 6 16 Output current calibration page...

Страница 132: ...connected to the am meter and the output is short circuit 3 Press Output Reset Button to output Stage 1 low current point 4 When READ VALUE 1 is stabilized press Save and the product will generate th...

Страница 133: ...ADG L Series Programmable DC Power Supply 125 Figure 6 19 Current indicated value and set value calibration page...

Страница 134: ...urrent point Please refer to Figure 6 22 4 When READ VALUE 1 is stabilized press SAVE and the product will generate the Stage 2 high current point 5 When READ VALUE 2 is stabilized press SAVE and the...

Страница 135: ...ADG L Series Programmable DC Power Supply 127 Figure 6 22 Output power calibration page...

Страница 136: ...uct maintenance regularly 7 1 Notice for maintenance 1 Pay attention to the safety summary and read the manual carefully 2 Ensure the power line input is cut off and the device has been shut down for...

Отзывы: