background image

Page 7

For technical questions, please call 1-888-866-5797.

ITEM 69674 

        

Sa

Fety

Setup

Opera

ti

O

n

Maintenance

components and controls (cont.)

The following are descriptions of the controls 

on the power panel. Your generator has 

sockets to power your products with circuit 

breakers to protect the voltage flow. 

1. 

i

O

engine Switch:  

Used to enable/disable Generator 

operation..  

  

2. 

ac receptacles:  

The Generator contains several 

AC receptacles to power tools and equipment.   

a. 

3-prong, duplex  

120 volt receptacle  

(neMa #5-20) 

4-prong, twistlock,  

120/240 volt receptacle 

(neMa #L14-30)

WarninG!  

Connect tools and equipment 

only to the Receptacle (120 volt or 240 volt) 

that is compatible with the electrical 

characteristics and rated capacities of 

the tools and equipment being used.  

3. 

On
OFF

circuit Breakers:  

The circuit breaker protects 

the Generator from overloading. The rating of the 

breaker and the load it protects are marked near 

the breaker. Should any of the Circuit Breakers trip, 

the Generator will stop the electricity output.  If this 

happens, unplug all loads from the Generator.  Allow 

the Generator to cool down.  Then, press the tripped 

Circuit Breaker, restart the Engine, and re‑attach 

loads. 

4. 

Dc receptacle: 

12 VDC Receptacle set provides a 

power source for 12 volt DC items.  

5. 

Grounding terminal:  

Prior to each use, set 

up the ground wire (not included) connection 

to the Grounding Terminal to properly ground 

the Generator. See Set up instructions 

to properly ground the Generator.

Содержание 69674

Страница 1: ...the product is intact and undamaged If any generator parts are missing or broken please call 1 888 866 5797 as soon as possible Visit our website at http www harborfreight com email our technical sup...

Страница 2: ...ecautions 1 Gasoline fuel and fumes are flammable and potentially explosive Use proper fuel storage and handling procedures Do not store fuel or other flammable materials nearby 2 Have multiple ABC cl...

Страница 3: ...l spectators at least six feet from the Engine during operation 7 Fire Hazard Do not fill gas tank while engine is running Do not operate if gasoline has been spilled Clean spilled gasoline before sta...

Страница 4: ...from exposed live electrical parts and connections to avoid sparking or arcing These events could ignite fumes or vapors 29 Stay alert watch what you are doing and use common sense when operating thi...

Страница 5: ...gles heavy duty work gloves and dust mask respirator during service 7 Maintain labels and nameplates on the equipment These carry important information If unreadable or missing contact Harbor Freight...

Страница 6: ...gasoline Capacity 6 1 Gallons 23L Engine Oil Type SAE 10W 30 above 32 F 5W 30 at 32 F or below Capacity 1 16 Quart 1 1L Run Time 50 load 12 hr Operational Volume 74 dB Available accessories Wheel kit...

Страница 7: ...r 240 volt that is compatible with the electrical characteristics and rated capacities of the tools and equipment being used 3 ON OFF Circuit Breakers The circuit breaker protects the Generator from o...

Страница 8: ...c equipment includes but is not limited to audio video equipment some television sets computers and printers Sensitive electronic equipment should be operated on approved inverter type generators or p...

Страница 9: ...he Fuel Cap 5 Wipe up any spilled fuel and allow excess to evaporate before starting engine To prevent FIRE do not start the engine while the smell of fuel hangs in the air Using the Generator Before...

Страница 10: ...etor Then pull the Starter Handle gently until resistance is felt Allow Cable to retract fully and then pull it quickly Repeat until the engine starts Note Do not let the Starter Handle snap back agai...

Страница 11: ...controller Do not overcharge a Connect the items that require the most wattage first b Connect inductive load appliances tools and equipment next Inductive loads are small hand tools and some small a...

Страница 12: ...s and amps can be multiplied together to get watts volts x amps watts To Calculate Additional Start Up Watts If They Are Not Listed For equipment with a motor Use the rated watts amount as an estimate...

Страница 13: ...o stop the engine in an emergency turn the Engine Switch off NOTICE Generator shut off under load may damage the generator and attached equipment Stopping the Engine Under Normal Conditions 1 Before t...

Страница 14: ...uipment instead Cleaning Maintenance and Lubrication Note This maintenance schedule is intended solely as a general guide If performance decreases or if equipment operates unusually check systems imme...

Страница 15: ...changing oil 1 Make sure the engine is stopped and is level 2 Close the Fuel Valve 3 Place a drain pan not included underneath the crankcase s drain plug 4 Remove the drain plug and if possible tilt t...

Страница 16: ...o remain idle for longer than 20 days prepare the Engine for storage as follows 1 CLEANING Wait for Engine to cool then clean Engine with dry cloth NOTICE Do not clean using water The water will gradu...

Страница 17: ...spark plug and pull the start handle several times to air out the chamber Reinstall spark plug and set Choke to START position 9 Replace Fuel Filter IGNITION SPARK RELATED 1 Spark plug cap not connect...

Страница 18: ...ipment Engine knocks 1 Old or low quality gasoline 2 Engine overloaded 3 Incorrect spark timing deposit buildup worn engine or other mechanical problems 1 Fill fuel tank with fresh 87 octane stabilize...

Страница 19: ...NTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUT...

Страница 20: ...pring Throttle Return 1 81 Rod Governor 1 82 Arm Governor 1 83 Bolt Governor Arm 1 84 Nut Flange M6 1 85 Cover Dust 1 86 Bolt Flange M5 10 3 87 Grommet Crankcase 1 88 Bolt Flange 4 89 Stay Comp Muffle...

Страница 21: ...Page 21 For technical questions please call 1 888 866 5797 ITEM 69674 Safety Setup Operation Maintenance Assembly Diagram...

Страница 22: ...Page 22 For technical questions please call 1 888 866 5797 ITEM 69674 Safety Setup Operation Maintenance Assembly Diagram cont...

Страница 23: ...rd and Harbor Freight Tools HFT are pleased to explain the emissions control system warranty on your 2016 Small Off Road Engine In California new equipment that uses small off road engines must be des...

Страница 24: ...ices or repairs will be provided at all retail stores or by contacting HFT product support at 1 888 866 5797 or productsupport harborfreight com 6 The owner will not be charged for diagnostic labor th...

Отзывы: