background image

Page 12

For technical questions, please call 1-888-866-5797.

ITEM 69674 

        

Sa

Fety

Setup

Opera

ti

O

n

Maintenance

Before using the Generator, check that the products 

you want to plug into the unit are below the rated and 

maximum wattage ratings of the Generator. Use the 

Wattage Calculation Table below, and the watts listed 

on your products, to help calculate multiple  

wattage totals.   

 

to use the table:

1.  Add up the Running Watts for all items you 

would like to use at any given time

2.  Make sure that this total is under the 5,500 

running wattage of the generator.

3.  Find the single highest starting watts for 

the selected items and add to the total. 

4.  Make sure that this total is under the 

6,500 peak wattage of the generator.

5.  Plug in and turn on products from largest wattage 

to smallest. 

 

 

example

equipment

running

Watts

Electric Water Heater (2,000 + 0)

2,000

Television (400 + 0)

400

Lawn Mower (1,200 + 1,200)

1,200

Hand Drill (600 + 600)

600

total running Watts  

(must be less than 5,500)

4,200

Largest additional Start-up Watts

1,200

total Startup Watts needed for all loads 

(must be less than 6,500)

5,400

Wattage calculation table

equipment

running

Watts

total running Watts  

(must be less than 5,500)

Largest additional Start-up Watts

total Startup Watts needed for all loads 

(must be less than 6,500)

A generator that is rated more than the minimum 

required peak watts will last much longer than a 

generator that only supplies the exact watts needed.

to calculate Wattage

Volts and amps can be multiplied together to get watts (volts x 

amps = watts). 

to calculate additional Start-up Watts  

(if they are not Listed) 

 For equipment with a motor: Use the rated watts 

amount as an estimate of additional Start‑up Watts.

For most lights or heaters: 

there are no additional start‑up watts. 

calculating total Wattage of Devices used with the Generator

JOB Site

Device

running 

Watts

additional 

Start-up 

Watts

Air Compressor ‑ 1/2 HP

1000

1000

Table Saw ‑ 10"

1700

1300

Belt Sander ‑ 3"

1200

1200

Hand Drill ‑ 1/2"

600

600

Halogen Work Light

1000

0

Recipricating Saw

900

900

HOuSeHOLD

Device

running 

Watts

additional 

Start-up 

Watts

Computer w/ Monitor

800

0

Electric Clothes Dryer

5500

500

Electric Range

2100

0

Electric Water Heater

2000

0

Light Bulb ‑ 100 watts

100

0

Microwave ‑ 1000 watts

1000

200

Sump Pump ‑ 1/2 HP

1000

1100

Television

400

0

Washing Machine

1100

1100

Well Pump ‑ 1/2 HP

1000

1000

recreatiOn

Device

running 

Watts

additional 

Start-up 

Watts

AM/FM Radio

100

0

Electric Grill

1700

0

Inflator Pump

50

100

CD/DVD Player

100

0

Box Fan ‑ 20"

200

200

Coffee Maker

600

0

LaWn & GarDen

Device

running 

Watts

additional 

Start-up 

Watts

Hedge Trimmer

400

400

Pressure Washer

1200

1200

Lawn Mower

1200

1200

Edger

1000

1000

HeatinG & cOOLinG

Device

running 

Watts

additional 

Start-up 

Watts

Central AC ‑ 10,000 BTU

1500

1500

Furnace Fan ‑ 1/2 HP

900

1400

Space Heater

1800

0

Window AC ‑ 10,000 BTU

1200

600

eMerGency

Device

running 

Watts

additional 

Start-up 

Watts

Refrigerator/Freezer

700

1500

Radio

100

0

Wattage estimate charts

note:

 Wattages listed below are estimates for that type 

of equipment only. Check nameplate wattages on all 

loads before connecting to Generator. 

Содержание 69674

Страница 1: ...the product is intact and undamaged If any generator parts are missing or broken please call 1 888 866 5797 as soon as possible Visit our website at http www harborfreight com email our technical sup...

Страница 2: ...ecautions 1 Gasoline fuel and fumes are flammable and potentially explosive Use proper fuel storage and handling procedures Do not store fuel or other flammable materials nearby 2 Have multiple ABC cl...

Страница 3: ...l spectators at least six feet from the Engine during operation 7 Fire Hazard Do not fill gas tank while engine is running Do not operate if gasoline has been spilled Clean spilled gasoline before sta...

Страница 4: ...from exposed live electrical parts and connections to avoid sparking or arcing These events could ignite fumes or vapors 29 Stay alert watch what you are doing and use common sense when operating thi...

Страница 5: ...gles heavy duty work gloves and dust mask respirator during service 7 Maintain labels and nameplates on the equipment These carry important information If unreadable or missing contact Harbor Freight...

Страница 6: ...gasoline Capacity 6 1 Gallons 23L Engine Oil Type SAE 10W 30 above 32 F 5W 30 at 32 F or below Capacity 1 16 Quart 1 1L Run Time 50 load 12 hr Operational Volume 74 dB Available accessories Wheel kit...

Страница 7: ...r 240 volt that is compatible with the electrical characteristics and rated capacities of the tools and equipment being used 3 ON OFF Circuit Breakers The circuit breaker protects the Generator from o...

Страница 8: ...c equipment includes but is not limited to audio video equipment some television sets computers and printers Sensitive electronic equipment should be operated on approved inverter type generators or p...

Страница 9: ...he Fuel Cap 5 Wipe up any spilled fuel and allow excess to evaporate before starting engine To prevent FIRE do not start the engine while the smell of fuel hangs in the air Using the Generator Before...

Страница 10: ...etor Then pull the Starter Handle gently until resistance is felt Allow Cable to retract fully and then pull it quickly Repeat until the engine starts Note Do not let the Starter Handle snap back agai...

Страница 11: ...controller Do not overcharge a Connect the items that require the most wattage first b Connect inductive load appliances tools and equipment next Inductive loads are small hand tools and some small a...

Страница 12: ...s and amps can be multiplied together to get watts volts x amps watts To Calculate Additional Start Up Watts If They Are Not Listed For equipment with a motor Use the rated watts amount as an estimate...

Страница 13: ...o stop the engine in an emergency turn the Engine Switch off NOTICE Generator shut off under load may damage the generator and attached equipment Stopping the Engine Under Normal Conditions 1 Before t...

Страница 14: ...uipment instead Cleaning Maintenance and Lubrication Note This maintenance schedule is intended solely as a general guide If performance decreases or if equipment operates unusually check systems imme...

Страница 15: ...changing oil 1 Make sure the engine is stopped and is level 2 Close the Fuel Valve 3 Place a drain pan not included underneath the crankcase s drain plug 4 Remove the drain plug and if possible tilt t...

Страница 16: ...o remain idle for longer than 20 days prepare the Engine for storage as follows 1 CLEANING Wait for Engine to cool then clean Engine with dry cloth NOTICE Do not clean using water The water will gradu...

Страница 17: ...spark plug and pull the start handle several times to air out the chamber Reinstall spark plug and set Choke to START position 9 Replace Fuel Filter IGNITION SPARK RELATED 1 Spark plug cap not connect...

Страница 18: ...ipment Engine knocks 1 Old or low quality gasoline 2 Engine overloaded 3 Incorrect spark timing deposit buildup worn engine or other mechanical problems 1 Fill fuel tank with fresh 87 octane stabilize...

Страница 19: ...NTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUT...

Страница 20: ...pring Throttle Return 1 81 Rod Governor 1 82 Arm Governor 1 83 Bolt Governor Arm 1 84 Nut Flange M6 1 85 Cover Dust 1 86 Bolt Flange M5 10 3 87 Grommet Crankcase 1 88 Bolt Flange 4 89 Stay Comp Muffle...

Страница 21: ...Page 21 For technical questions please call 1 888 866 5797 ITEM 69674 Safety Setup Operation Maintenance Assembly Diagram...

Страница 22: ...Page 22 For technical questions please call 1 888 866 5797 ITEM 69674 Safety Setup Operation Maintenance Assembly Diagram cont...

Страница 23: ...rd and Harbor Freight Tools HFT are pleased to explain the emissions control system warranty on your 2016 Small Off Road Engine In California new equipment that uses small off road engines must be des...

Страница 24: ...ices or repairs will be provided at all retail stores or by contacting HFT product support at 1 888 866 5797 or productsupport harborfreight com 6 The owner will not be charged for diagnostic labor th...

Отзывы: