background image

Page 18

For technical questions, please call 1-888-866-5797.

ITEM 69674 

        

Sa

Fety

Setup

Opera

ti

O

n

Maintenance

problem

possible causes

probable Solutions

Engine misfires

1.  Spark plug cap loose.
2.  Incorrect spark plug gap or 

damaged spark plug.

3.  Defective spark plug cap.
4.  Old or low quality gasoline. 

 

5.  Incorrect compression.

1.  Check wire connections.
2.  Re‑gap or replace spark plug. 

3.  Replace spark plug cap.
4.  Use only fresh 87+ octane stabilizer‑treated 

unleaded gasoline.

 

Do not use gasoline with more than 

10% ethanol (e15, e20, e85, etc.).

5.  Diagnose and repair compression. 

(Use 

engine will not start: 

cOMpreSSiOn reLateD

 section.)

Engine stops 

suddenly

1.  Low oil shutdown. 

2.  Fuel tank empty or full of impure or low 

quality gasoline. 

 

3.  Defective fuel tank cap creating 

vacuum, preventing proper fuel flow.

4.  Faulty magneto.
5.  Disconnected or improperly 

connected spark plug cap.

1.  Fill engine oil to proper level.  Check 

engine oil before EVERY use.

2.  Fill fuel tank with fresh 87+ octane stabilizer‑

treated unleaded gasoline.

 

Do not use gasoline with more than 

10% ethanol (e15, e20, e85, etc.).

3.  Test/replace fuel tank cap. 

4.  Have qualified technician service magneto.
5.  Secure spark plug cap.

Engine stops when 

under heavy load

1.  Dirty air filter.
2.  Engine running cold.

1.  Clean or replace element.
2.  Allow engine to warm up prior 

to operating equipment.

Engine knocks

1.  Old or low quality gasoline. 

 

 

2.  Engine overloaded.
3.  Incorrect spark timing, deposit buildup, 

worn engine, or other mechanical problems.

1.  Fill fuel tank with fresh 87+ octane stabilizer‑

treated unleaded gasoline. 

  

Do not use gasoline with more than 

10% ethanol (e15, e20, e85, etc.).

2.  Do not exceed equipment’s load rating.
3.  Have qualified technician diagnose 

and service engine.

Engine backfires

1.  Impure or low quality gasoline. 

 

 

2.  Engine too cold. 

3.  Intake valve stuck or overheated engine. 

4.  Incorrect timing.

1.  Fill fuel tank with fresh 87+ octane stabilizer‑

treated unleaded gasoline. 

  

Do not use gasoline with more than 

10% ethanol (e15, e20, e85, etc.).

2.  Use cold weather fuel and oil 

additives to prevent backfiring.

3.  Have qualified technician diagnose 

and service engine.

4.  Check engine timing.

Product doesn’t 

have power.

1.  Product not plugged in properly. 

2.  Circuit Breaker tripped. 

3.  Product needs service.

1.  Turn off and unplug the product, then 

plug it back in again and turn on.

2.  Turn off and unplug product, Reset Circuit 

Breaker. Plug in product and turn on.

3.  Have product repaired.

Product begins to 

operate abnormally. 

1.  Problem with appliance. 

 

2.  Rated load capacity exceeded.

1.  Immediately unplug appliance. Have 

appliance repaired by a qualified 

technician, or replace appliance.

2.  Lower the number of items plugged into the 

generator to stay within the rated capacity, 

or use a more powerful generator.

Follow all safety precautions whenever diagnosing or servicing the equipment or engine.

troubleshooting (cont.)

Содержание 69674

Страница 1: ...the product is intact and undamaged If any generator parts are missing or broken please call 1 888 866 5797 as soon as possible Visit our website at http www harborfreight com email our technical sup...

Страница 2: ...ecautions 1 Gasoline fuel and fumes are flammable and potentially explosive Use proper fuel storage and handling procedures Do not store fuel or other flammable materials nearby 2 Have multiple ABC cl...

Страница 3: ...l spectators at least six feet from the Engine during operation 7 Fire Hazard Do not fill gas tank while engine is running Do not operate if gasoline has been spilled Clean spilled gasoline before sta...

Страница 4: ...from exposed live electrical parts and connections to avoid sparking or arcing These events could ignite fumes or vapors 29 Stay alert watch what you are doing and use common sense when operating thi...

Страница 5: ...gles heavy duty work gloves and dust mask respirator during service 7 Maintain labels and nameplates on the equipment These carry important information If unreadable or missing contact Harbor Freight...

Страница 6: ...gasoline Capacity 6 1 Gallons 23L Engine Oil Type SAE 10W 30 above 32 F 5W 30 at 32 F or below Capacity 1 16 Quart 1 1L Run Time 50 load 12 hr Operational Volume 74 dB Available accessories Wheel kit...

Страница 7: ...r 240 volt that is compatible with the electrical characteristics and rated capacities of the tools and equipment being used 3 ON OFF Circuit Breakers The circuit breaker protects the Generator from o...

Страница 8: ...c equipment includes but is not limited to audio video equipment some television sets computers and printers Sensitive electronic equipment should be operated on approved inverter type generators or p...

Страница 9: ...he Fuel Cap 5 Wipe up any spilled fuel and allow excess to evaporate before starting engine To prevent FIRE do not start the engine while the smell of fuel hangs in the air Using the Generator Before...

Страница 10: ...etor Then pull the Starter Handle gently until resistance is felt Allow Cable to retract fully and then pull it quickly Repeat until the engine starts Note Do not let the Starter Handle snap back agai...

Страница 11: ...controller Do not overcharge a Connect the items that require the most wattage first b Connect inductive load appliances tools and equipment next Inductive loads are small hand tools and some small a...

Страница 12: ...s and amps can be multiplied together to get watts volts x amps watts To Calculate Additional Start Up Watts If They Are Not Listed For equipment with a motor Use the rated watts amount as an estimate...

Страница 13: ...o stop the engine in an emergency turn the Engine Switch off NOTICE Generator shut off under load may damage the generator and attached equipment Stopping the Engine Under Normal Conditions 1 Before t...

Страница 14: ...uipment instead Cleaning Maintenance and Lubrication Note This maintenance schedule is intended solely as a general guide If performance decreases or if equipment operates unusually check systems imme...

Страница 15: ...changing oil 1 Make sure the engine is stopped and is level 2 Close the Fuel Valve 3 Place a drain pan not included underneath the crankcase s drain plug 4 Remove the drain plug and if possible tilt t...

Страница 16: ...o remain idle for longer than 20 days prepare the Engine for storage as follows 1 CLEANING Wait for Engine to cool then clean Engine with dry cloth NOTICE Do not clean using water The water will gradu...

Страница 17: ...spark plug and pull the start handle several times to air out the chamber Reinstall spark plug and set Choke to START position 9 Replace Fuel Filter IGNITION SPARK RELATED 1 Spark plug cap not connect...

Страница 18: ...ipment Engine knocks 1 Old or low quality gasoline 2 Engine overloaded 3 Incorrect spark timing deposit buildup worn engine or other mechanical problems 1 Fill fuel tank with fresh 87 octane stabilize...

Страница 19: ...NTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUT...

Страница 20: ...pring Throttle Return 1 81 Rod Governor 1 82 Arm Governor 1 83 Bolt Governor Arm 1 84 Nut Flange M6 1 85 Cover Dust 1 86 Bolt Flange M5 10 3 87 Grommet Crankcase 1 88 Bolt Flange 4 89 Stay Comp Muffle...

Страница 21: ...Page 21 For technical questions please call 1 888 866 5797 ITEM 69674 Safety Setup Operation Maintenance Assembly Diagram...

Страница 22: ...Page 22 For technical questions please call 1 888 866 5797 ITEM 69674 Safety Setup Operation Maintenance Assembly Diagram cont...

Страница 23: ...rd and Harbor Freight Tools HFT are pleased to explain the emissions control system warranty on your 2016 Small Off Road Engine In California new equipment that uses small off road engines must be des...

Страница 24: ...ices or repairs will be provided at all retail stores or by contacting HFT product support at 1 888 866 5797 or productsupport harborfreight com 6 The owner will not be charged for diagnostic labor th...

Отзывы: