9.  Improper connections to a building electrical system 

can allow electrical current from the generator to 

backfeed into the utility lines. Such backfeed may 

electrocute utility company workers or others who 

contact the lines during a power outage, and the 

generator may explode, burn, or cause fires when 

utility power is restored. Consult the utility company 

and a qualified electrician if intending to 

use the generator for back up power.

10. Do not operate the Generator before grounding. 

The Generator must be earth‑grounded 

in accordance with all relevant electrical 

codes and standards before operation.

Operating precautions

1. 

carBOn MOnOXiDe HaZarD 

using a generator indoors can KiLL 

yOu in MinuteS. 

Generator exhaust contains carbon 

monoxide.  This is a poison you cannot 

see or smell. 

NEVER use inside a home or garage, EVEN IF 

doors and windows are open. 

Only use OUTSIDE and far away from windows, 

doors, and vents.

2.  Never use a generator indoors,  including in 

garages, basements, crawlspaces and sheds. 

Opening doors and windows or using fans will NOT 

prevent carbon monoxide build up in the home.

3.  When using generators, keep them outdoors 

and far away from open doors, windows, 

and vents to avoid toxic levels of carbon 

monoxide from building up indoors.

4.  If you start to feel sick, dizzy, or weak while 

using a generator, get to fresh air right away. 

The carbon monoxide from generators can 

quickly lead to full incapacitation and death.

5.  Keep children away from the equipment, 

especially while it is operating. 

6.  Keep all spectators at least six feet 

from the Engine during operation.

7.  Fire Hazard! Do not fill gas tank while engine is 

running. Do not operate if gasoline has been spilled. 

Clean spilled gasoline before starting engine. 

Do not operate near pilot light or open flame.

8.  Do not touch engine during use. Let 

engine cool down after use. 

9.  Never store fuel or other flammable 

materials near the engine.

10. If the plugged in product operates abnormally 

or unusually slow, immediately stop using the 

generator as a power source.  Always read and 

adhere to the instruction manual of the product 

to be powered, to make sure that it can be safely 

and efficiently powered by a portable generator.  

11.  Before connecting an appliance or power cord 

to the generator:  Make sure that it is in good 

working order. Faulty appliances or power cords 

can create a potential for electrical shock.

12. Do not exceed the maximum power rating of the 

generator. Make sure that the total electrical rating 

of the all of the tools or appliances plugged into 

the generator at the same time does not exceed 

that of the generator. Check that the startup surge 

will not be beyond the limit of the Generator. 

Power levels between rated and maximum 

may be used for no more than 30 minutes.

13. Avoid substantially overloading which will trip the 

circuit breaker. Exceeding the time limit for maximum 

power operation or slightly overloading the generator 

may not switch the circuit breaker or circuit protector 

OFF, but will shorten the service life of the generator.

14. Do not attempt to connect or disconnect 

load connections while standing in 

water, or on wet or soggy ground.

15. Do not touch electrically energized parts of 

the Generator and interconnecting cables 

or conductors with any part of the body, or 

with any non‑insulated conductive object.

Set up precautions (cont.)

Содержание 69674

Страница 1: ...the product is intact and undamaged If any generator parts are missing or broken please call 1 888 866 5797 as soon as possible Visit our website at http www harborfreight com email our technical sup...

Страница 2: ...ecautions 1 Gasoline fuel and fumes are flammable and potentially explosive Use proper fuel storage and handling procedures Do not store fuel or other flammable materials nearby 2 Have multiple ABC cl...

Страница 3: ...l spectators at least six feet from the Engine during operation 7 Fire Hazard Do not fill gas tank while engine is running Do not operate if gasoline has been spilled Clean spilled gasoline before sta...

Страница 4: ...from exposed live electrical parts and connections to avoid sparking or arcing These events could ignite fumes or vapors 29 Stay alert watch what you are doing and use common sense when operating thi...

Страница 5: ...gles heavy duty work gloves and dust mask respirator during service 7 Maintain labels and nameplates on the equipment These carry important information If unreadable or missing contact Harbor Freight...

Страница 6: ...gasoline Capacity 6 1 Gallons 23L Engine Oil Type SAE 10W 30 above 32 F 5W 30 at 32 F or below Capacity 1 16 Quart 1 1L Run Time 50 load 12 hr Operational Volume 74 dB Available accessories Wheel kit...

Страница 7: ...r 240 volt that is compatible with the electrical characteristics and rated capacities of the tools and equipment being used 3 ON OFF Circuit Breakers The circuit breaker protects the Generator from o...

Страница 8: ...c equipment includes but is not limited to audio video equipment some television sets computers and printers Sensitive electronic equipment should be operated on approved inverter type generators or p...

Страница 9: ...he Fuel Cap 5 Wipe up any spilled fuel and allow excess to evaporate before starting engine To prevent FIRE do not start the engine while the smell of fuel hangs in the air Using the Generator Before...

Страница 10: ...etor Then pull the Starter Handle gently until resistance is felt Allow Cable to retract fully and then pull it quickly Repeat until the engine starts Note Do not let the Starter Handle snap back agai...

Страница 11: ...controller Do not overcharge a Connect the items that require the most wattage first b Connect inductive load appliances tools and equipment next Inductive loads are small hand tools and some small a...

Страница 12: ...s and amps can be multiplied together to get watts volts x amps watts To Calculate Additional Start Up Watts If They Are Not Listed For equipment with a motor Use the rated watts amount as an estimate...

Страница 13: ...o stop the engine in an emergency turn the Engine Switch off NOTICE Generator shut off under load may damage the generator and attached equipment Stopping the Engine Under Normal Conditions 1 Before t...

Страница 14: ...uipment instead Cleaning Maintenance and Lubrication Note This maintenance schedule is intended solely as a general guide If performance decreases or if equipment operates unusually check systems imme...

Страница 15: ...changing oil 1 Make sure the engine is stopped and is level 2 Close the Fuel Valve 3 Place a drain pan not included underneath the crankcase s drain plug 4 Remove the drain plug and if possible tilt t...

Страница 16: ...o remain idle for longer than 20 days prepare the Engine for storage as follows 1 CLEANING Wait for Engine to cool then clean Engine with dry cloth NOTICE Do not clean using water The water will gradu...

Страница 17: ...spark plug and pull the start handle several times to air out the chamber Reinstall spark plug and set Choke to START position 9 Replace Fuel Filter IGNITION SPARK RELATED 1 Spark plug cap not connect...

Страница 18: ...ipment Engine knocks 1 Old or low quality gasoline 2 Engine overloaded 3 Incorrect spark timing deposit buildup worn engine or other mechanical problems 1 Fill fuel tank with fresh 87 octane stabilize...

Страница 19: ...NTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUT...

Страница 20: ...pring Throttle Return 1 81 Rod Governor 1 82 Arm Governor 1 83 Bolt Governor Arm 1 84 Nut Flange M6 1 85 Cover Dust 1 86 Bolt Flange M5 10 3 87 Grommet Crankcase 1 88 Bolt Flange 4 89 Stay Comp Muffle...

Страница 21: ...Page 21 For technical questions please call 1 888 866 5797 ITEM 69674 Safety Setup Operation Maintenance Assembly Diagram...

Страница 22: ...Page 22 For technical questions please call 1 888 866 5797 ITEM 69674 Safety Setup Operation Maintenance Assembly Diagram cont...

Страница 23: ...rd and Harbor Freight Tools HFT are pleased to explain the emissions control system warranty on your 2016 Small Off Road Engine In California new equipment that uses small off road engines must be des...

Страница 24: ...ices or repairs will be provided at all retail stores or by contacting HFT product support at 1 888 866 5797 or productsupport harborfreight com 6 The owner will not be charged for diagnostic labor th...

Отзывы: