13. Return the treadmill to an upright position.
14. Plug the power cord into the wall outlet and switch the treadmill circuit breaker “ON”.
Verify the lift motor calibration
15. Access the Hardware Validation service menu (51765761) and select the
Incline
Test
, see .
"Standard Service Menus" on page 36
16. Use the incline controls to verify the nominal A/D values at -2%, 0%, and 15%:
Incline Level
A/D Value
-2%
Nominal value: 13 ±5 @ -2% incline
0%
Nominal value: 37 ±5 @0% incline
15%
Nominal value: 242 ±5 @ 15% incline
17. Exit Hardware Validation service menu.
18. Re-install the hood.
19. Start a manual Workout. Operate the
INCLINE
controls through the minimum and
maximum limits while verifying incline operation.
20. Verify operation and return to service, see (
"Operation Verification" on page 17
).
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.
Page 61
5 Adjustment Procedures
Lift Motor Calibration