Battery Replacement
(Spinner®
Chrono
1
™ Power models only)
About
This procedure provides instruction to determine the condition of the battery and replace-
ment procedure.
Specifications
Battery Voltage
Specification
Battery Specification
6 VDC, 1.2 AH
GOOD battery state*
5.8 - 6.6 VDC*
LOW battery state*
5.5 - 5.7 VDC*
Console OFF state*
< 5.4 VDC*
Charging voltage
(while pedaling)
7.5 VDC max
Note: * static voltage measurements: no pedal movement and no
power adapter connected.
Determining the battery condition
If the measured voltage is below 5.5 Vdc, charge the battery by pedaling greater than 55
rpm (or using an optional battery adapter) until the battery static (non-pedaling) voltage level
1
Spinner® Chrono™ Power bike.
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.
Page 43
5 Replacement Procedures
Battery Replacement