Blown Battery Fuse Troubleshooting
Use this procedure to help troubleshoot a failed "blown" battery fuse.
Main battery fuse failure
An indication that the battery fuse has failed is that the machine will operate as normal except
that the incline lift function does not operate,
1. Remove the main battery fuse from the inline fuse inline holder and verify condition. Use
an ohm meter to verify that there is continuity (zero ohms) between the two fuse con-
nection pins.
a. If the fuse is good, replace the removed fuse.
b. If the fuse is bad, replace the fuse.
2. Make sure the battery is charged and properly connected, see
3. Make sure that the battery positive and negative cables are installed correctly and
securely connected at both ends of the battery power cable.
4. Switch the power ON. Verify that the machine power has been restored. Wait for a few
minutes and make sure the fuse does not fail again.
a. If the fuse fails after power up, the fuse is not causing the power failure, continue
troubleshooting the cause of the electrical power failure.
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.