C932, C932i, C934, C936i Treadmilll
Page 34
10. Feed the three pin lift motor connector through the grommet in the lower PCA bracket and
insert it in the J7 connector of the lower PCA.
11. Insert the large lift motor connector in the J1 connector of the lower PCA.
12. On 120 VAC treadmills only, remove the jumper from terminals M1 and M6 from the original
lower PCA and install it between terminals M1 and M6 of the replacement lower PCA.
Do not
install this jumper on 240VAC treadmills, do so may severely damage the lower
PCA.
13. Dress all of the above wiring into the appropriate wire clips along their routing.
14. Insert the AC line cord from the AC outlet. Set the treadmill circuit breaker in the “on”
position.
15. Check treadmill operation per Procedure 3.
Содержание C932
Страница 38: ...C932 C932i C934 C936i Treadmilll Page 38 16 Check treadmill operation per Procedure 3...
Страница 40: ...C932 C932i C934 C936i Treadmilll Page 40 9 Check treadmill operation per Section 3...
Страница 49: ...C932 C932i C934 C936i Treadmill Page 49 Block Diagram 7 2 C932 C932i C934 C936i...