Procedure 2.1 - Accessing the Hardware Validation Program
The treadmill's diagnostic program consists of the following modes:
•
Display Test
•
Keyboard Test
•
Heart Rate Test
•
Lift Test
•
Belt Speed Test
•
Belt Power Test
Procedure
1.
The keys on the display are hypothetically numbered 1 to 7 from left to right. See Diagram
2.1. The
RESET
is key number 4.
2.
Plug the power cord into the wall outlet, then turn on the treadmill with the circuit breaker.
3.
Press keys
RESET,5,1,7,6,5,7,6,1
, sequentially.
4.
For C932 and C932i treadmills, skip to step 30. For C934 and C936i treadmills, continue
with step 5.
5.
The display will momentarily read
DISPLAY
and then alternately illuminate every LED on
the display. Check all LED positions to ensure that all of the LED’s are functioning. Press the
ENTER
key to continue.
Diagram 2.1 - C934 Treadmill Display
Key # 7
RESET Key
Key # 1