P
RO
V
U
PD6100 Strain Gauge, Load Cell, & mV Meter Instruction Manual
10
Safety Information
CAUTION
:
Read complete
instructions prior to installation
and operation of the meter.
WARNING
:
Risk of electric
shock or personal injury.
WARNING!
Hazardous voltages exist within enclosure.
Installation and service should be performed
only by trained service personnel.
Installation
There is no need to remove the meter from its case to complete the installation, wiring, and setup
of the meter for most applications.
Instructions are provided for changing the sensor power supply to output 5 or 10 VDC instead of
24 VDC on page 11.
Unpacking
Remove the meter from box. Inspect the packaging and contents for damage. Report damages, if
any, to the carrier.
If any part is missing or the meter malfunctions, please contact your supplier or the factory for
assistance.
Panel Mounting Instructions
Prepare a standard 1/8 DIN panel cutout – 3.622" x 1.772" (92 mm x 45 mm). Refer to Figure below,
for more details.
Clearance: allow at least 6.0" (152 mm) behind the panel for wiring.
Panel thickness: 0.04" - 0.25" (1.0 mm - 6.4 mm).
Recommended minimum panel thickness to maintain Type 4X
rating: 0.06" (1.5 mm) steel panel, 0.16" (4.1 mm) plastic panel.
Remove the two mounting brackets provided with the meter (back-off the two screws so that there is ¼"
(6.4 mm) or less through the bracket. Slide the bracket toward the front of the case and remove).
Insert meter into the panel cutout.
Install mounting brackets and tighten the screws against the panel. To achieve a proper seal, tighten
the mounting bracket screws evenly until meter is snug to the panel along its short side. DO NOT
OVER TIGHTEN, as the rear of the panel may be damaged.
Figure 1. 1/8 DIN Panel Cutout
Dimensions
Figure 2. Panel Mounting Details
!
3.622" (92 mm)
1.772"
(45mm)
Panel Cutout
to DIN 43700
Square Corners to 0.060"
(1.5mm) Max Radius
A
B
Tolerances:
A: +0.032 (+0.8mm)
-0.000 (-0.0mm)
B: +0.024 (+0.6mm)
-0.000 (-0.0mm)
www.
.com
1.800.561.8187