![PRECISION DIGITAL PD6200 Скачать руководство пользователя страница 83](http://html1.mh-extra.com/html/precision-digital/pd6200/pd6200_instruction-manual_1594044083.webp)
Model PD6200 Analog Input Rate/Totalizer
Instruction Manual
83
Reset Meter to Factory Defaults
When the parameters have been changed in a way that is difficult to
determine what’s happening, it might be better to start the setup process
from the factory defaults.
Instructions to load factory defaults:
1. Enter
the
Advanced Features
menu. See
Advanced Features Menu
,
page 66.
2. Press Up arrow to go to
Diagnostics
menu
3. Press and hold Right arrow for five seconds, press
Enter when display flashes
reset
.
Note: If Enter is not pressed within three seconds, the display re-
turns to the
Diagnostics
menu.
4. The meter goes through an initialization sequence (similar as on
power-up), and loads the factory default settings.
996000
G P d
Run Mode
20.000
34568.9
reset
diaG
Press & hold Menu for
3 sec to access
Advanced features
Press & hold right
arrow for
3 sec to reset meter