– 19 –
WIRING DIAGRAM
1000
750
500
250
0
6
20
10
0
30
Load Limitations 4-20mA Output Only
RL-Loop Resistance in Ohms
Loop Supply Voltage (Vdc)
OPERATING
REGION
Vdc MIN = 12V + [0.022A X (RL) ]
R
L
= R
S
+ R
W
R
L
= Loop Resistance (ohms)
R
S
= Sense Resistance (ohms)
R
w
= Wiring Resistance (ohms)
I&M008-10136-DIG PDC 7-05_layput 8/4/11 2:42 PM Page 19