Model PD6262 Analog Dual-Input Rate/Totalizer Instruction Manual
93
Parameter Display
Default
Setting
User
Setting
Scaling, (channel A)
Scal a
Input 1, channel A
InP 1
4.000 mA
Display 1, channel A
Dis 1
4.000
Input 2, channel A
InP 2
20.000 mA
Display 2, channel A
Dis 2
20.000
Scaling (channel B)
Scal b
Input 1, channel B
InP 1
4.000 mA
Display 1, channel B
Dis 1
4.000
Input 2, channel B
InP 2
20.000 mA
Display 2, channel B
Dis 2
20.000
Total setup
Tsetup
Time base, channel A
Tbase
Sec
Total conversion factor,
Ch-A
T CF
1.000
Grand total conversion
factor, Ch-A
Gt CF
1.000
Time base, channel B
Tbase
Sec
Total conversion factor,
Ch-B
T CF
1.000
Grand total conversion
factor, Ch-B
Gt CF
1.000
Total reset
Treset
Total reset, channel A
T rst
Manual
Grand total reset, Ch-A
Gt rst
Manual
Total reset, channel B
T rst
Manual
Grand total reset, Ch-B
Gt rst
Manual
Display assignment
Dsplay
Big display
D Ch-A
Channel A
Little display
d Ch-B
Channel B
Display intensity
d-Inty
8