Operating the stapler
Regulating the stapler with the operating pressure
You can set the penetration depth of the stapler into the material by regulating the operating
pressure. At a higher operating pressure, the nails are driven deeper into the material; setting a
lower operating pressure reduces the penetration depth.
Set the operating pressure to achieve the required penetration depth. This has the
following benefits:
•
you save energy (compressed air),
•
you reduce the noise level, and
•
you reduce the wear of the stapler.
Proceed as follows to set the operating pressure:
➢
Adjust the pressure at the pressure valve of the compressor or compressed air system.
➢
Observe the pressure reading.
Checking the penetration depth
➢
Shoot a staple into a sample workpiece with the same characteristics as the processing
material.
➢
Repeat these steps until you have set the required penetration depth.