14
15
ANALOG LIMIT SWITCH INSTALLATION
1st Step:
With the gate closed, place the magnet support on the rack, positioned
facing the operator’s REED. This magnet will act as a closing limit switch.
2nd Step:
Fully open the gate and place the other magnet support on the rack,
facing the operator’s REED. This magnet will act as the opening limit switch.
3rd Step:
Start the engine and observe if the REED’s are shutting down correctly. If
necessary, invert the board connector.
Once the magnet supports are fixed, make the final adjustments, moving them to
the right or left, down or up, according to the desired adjustment.
4th Step:
To finish installing the operator, it is mandatory, before it works, to screw
the fairing with 10 screws M8 x 20 mm.
SUPPORT ADJUSTMENT