System Setup and Operation
CIRAS-2 Operator's Manual Version 2.04
- 44 -
Manual PLC
PLC4 (B) broadleaf (2.5 cm
2
head plate)
PLC4 (N) narrow leaf (10 cm
2
head plate)
PLC4 (C) conifer (10 cm
2
head plate)
PLC4 (P) pod (10 cm
2
head plate)
Closed System Chamber
SRC-1
CPY-2
CPY-4 (146 mm diameter)
Other
Open System Chamber
CPY-3 5 litre Canopy Assimilation (150 mm diameter)
CPY-3 20 litre Canopy Assimilation (300 mm diameter)
CPY-3 100 litre Canopy Assimilation (500 mm diameter)
CFX-1 (for soil respiration)
CFX-2 (for soil respiration)
Chlorophyll Fluorescence Module
CFM (combined with PLC6 (U) LED light unit)
Custom Chamber
[CC] (based on open
or
closed system chambers)
Oxygen Probe
Not Applicable
Some Accessories are no longer available. Environmental sensors attached to
Probe
input such as the
PAR sensor and Soil Temperature Probe are detected automatically and do not require selection as
Accessories. If you have any questions as to which cuvette or probe type you have, refer to the original
paperwork (i.e. invoice from PP Systems), the Appendix at the back of this manual or contact PP
Systems.
Add Custom Accessory
Primarily for use with your custom-built or existing chamber. In the
Settings
dialog, select the PP Systems
Accessory that most closely matches your chamber. Click
Add custom accessory
to call up the
Custom Chamber Type
dialog.
„Chamber Base Type‟ and „Probe Base Type‟ default to your selection in
the Accessory list
. Narrow your selection further in the „Probe Base Type‟ dropdown list. Enter a custom
chamber [CC] name in the ‟Name‟ field and an optional Description. Depending on the „Chamber Base
Type‟, additional parameters, such as System Volume, may be required.
Custom Cuvette Options
is
used for leaf cuvette and small assimilation chambers. If this is not grayed out, click the button and enter
any „Serial Number‟ and estimated „Boundary Layer‟ and „Leaf Area‟ for the cuvette. Note that these can
be estimated and resulting data recalculated at a later time.