Chapter 5 Function parameter
51
Ch
ap
ter 5
419.
E3.02
Virtual VDI3 terminal function
selection
0 to 50
0
★
420.
E3.03
Virtual VDI4 terminal function
selection
0 to 50
0
★
421.
E3.04
Virtual VDI5 terminal function
selection
0 to 50
0
★
422.
E3.05 Virtual VDI terminal status set
Units digit:Virtual VDI1
Tens digit:Virtual VDI2
Hundreds digit:Virtual VDI3
Thousands digit:Virtual VDI4
Tens of thousands:Virtual VDI5
00000
★
423.
E3.06
Virtual VDI terminal effective
status set mode
Units digit:Virtual VDI1
Tens digit:Virtual VDI2
Hundreds digit:Virtual VDI3
Thousands digit:Virtual VDI4
Tens of thousands:Virtual VDI5
11111
★
424.
E3.07
AI1 terminal as a function
selection of DI
0 to 50
0
★
425.
E3.08
AI2 terminal as a function
selection of DI
0 to 50
0
★
426.
E3.09
Panel potentiometer as a
function selection of DI
0 to 50
427.
E3.10
AI as DI effective mode
selection
Units digit
:
AI1
0:High level effectively
1:Low level effectively
Tens digit:AI2(0 to 1,same as
units digit)
Hundreds digit: Panel
potentiometer(0 to 1,same as
units digit)
000
★
428.
E3.11
Virtual VDO1 output function
selection
0 to 40
0
☆
429.
E3.12 Virtual VDO2 output function
0 to 40
0
☆
430.
E3.13 Virtual VDO3 output function 0 to 40
0
☆
431.
E3.14 Virtual VDO4 output function 0 to 40
0
☆
432.
E3.15 Virtual VDO5 output function 0 to 40
0
☆
433.
E3.16
VDO output terminal effective
status selection
Units digit:VDO1
0:Positive logic
1:Negative logic
Tens digit: VDO2(0 to 1,same as
above)
Hundreds digit:VDO3(0 to
1,same as above)
Thousands digit:VDO4(0 to
00000
☆