No. Code
Parameter name
Setting range
Factory
setting
Chan
ge
42. F0.00 Motor control manner
0.Vector control W/O PG
1.Vector control W/ PG
2.V/F control
2
★
43. F0.01 Keyboard set frequency
0.00Hz to F0.19 (maximum
frequency)
50.00Hz
☆
44. F0.02 Frequency command resolution
1: 0.1Hz
;
2: 0.01Hz
2
★
45. F0.03 Frequency source master setting
0 to 10
0
★
46. F0.04
Frequency source auxiliary
setting
0 to 10
0
★
47. F0.05
Reference object selection for
frequency source auxiliary
setting
0. relative to maximum
frequency
1.relative to master frequency
source 1
2. relative to master frequency
source 2
0
☆
48. F0.06
Frequency source auxiliary
setting range
0% to 150%
100%
☆
49. F0.07
Frequency source superimposed
selection
Units digit: frequency source
selection
Tens digit: arithmetic
relationship of master and
auxiliary for frequency source
00
☆
50. F0.08
Frequency source offset
frequency when superimposing
0.00Hz to F0.19(maximum
frequency)
0.00Hz
☆
51. F0.09
Shutdown memory selection for
digital set frequency
0: W/O memory
1: With memory
1
☆
52. F0.10
Frequency command UP /
DOWN reference when running
0: Running frequency
1: Set frequency
0
★
53. F0.11 Command source selection
0.Keyboard control (LED off)
1.Terminal block control (LED
on)
2.Communications command
control (LED flashes)
3. Keyboard
Communications command
control
4. Keyboard
Communications command
Terminal block
control
0
☆
54. F0.12
Binding frequency source for
command source
Units digit: binding frequency
source selection for operation
panel command
000
☆