CAUTION
If the power supply is operated with load
power lines disconnected and sensing line
connected, internal power supply damage
may occur. (Output current then flows
through sensing terminals.)
Connect sensing leads from the load positive to J1-13 and the load negative to J1-12.
A shielded, twisted-pair, hookup wire is recommended to avoid potential noise
interference.
3.6
REMOTE OUTPUT ON/OFF CONTROL
Remote on/off control may be accomplished by contact closure or by an isolated
external AC/DC or TTL/CMOS voltage source.
1. Remote on/off by contact closure. Output is on when contacts are closed.
See Figure 3-8 for connection requirements.
2. Remote on/off control may be accomplished by an external 12 to 240 VAC or
6 to 120 VDC or TTL/CMOS source. Application of AC/DC or high state
TTL/CMOS voltage will turn on the power supply. See Figures 3-9 and 3-10
for connection requirements.
3.7
REMOTE OVERVOLTAGE SET
A remote DC voltage source can be connected externally between terminals J1-3
(REM OV SET) and J1-6 (COM) to set the output overvoltage trip level. A 0-5 VDC
signal equals 0-100% of rated output voltage. See Figure 3-11 for connection
requirements.
Do not program the remote overvoltage set point greater than 10%
(5.5V) above the power supply rated voltage as internal power supply damage
may occur.
NOTE
The following modes of operation are used
for applications requiring more current or
voltage than is available from a single
power supply. To meet the requirements for
greater output voltage or current, two
supplies may be connected in series or
parallel.
M550001-01
3-7
Содержание D3 Series
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 25: ...Figure 2 4 P83 Outline Drawing 5 0KW to 15KW Output Voltage 80 V POWER VOLTAGE CURRENT M550001 01 2 9 ...
Страница 26: ...Figure 2 5 P66 Outline Drawing 13 3KW to 20kW Output Voltage 60 V M550001 01 2 10 POWER VOLTAGE CURRENT ...
Страница 27: ...Figure 2 6 P86 Outline Drawing 20KW to 30KW Output Voltage 80 V M550001 01 2 11 POWER VOLTAGE CURRENT ...
Страница 28: ...This page intentionally left blank M550001 01 2 12 ...
Страница 44: ...This page intentionally left blank M550001 01 3 16 ...
Страница 56: ...INPUT FILTER CONVERTER ASSEMBLY CONTROL ASSEMBLY Figure 4 1 P62 Internal Layout M550001 01 4 12 ...
Страница 59: ...Figure 4 4 P83 P86 Internal Layout M550001 01 4 15 ...
Страница 60: ...Figure 4 5 P83 P86 Converter Card M550001 01 4 16 ...
Страница 61: ...Figure 4 6 P63 P66 Converter Card M550001 01 4 17 ...
Страница 62: ...This page intentionally left blank M550001 01 4 18 ...