Table 5-2
Inspection and Corrective Action
ITEM
INSPECT FOR
CORRECTIVE ACTION
External Connector
plugs and jacks
Chassis, fan &
extruded heatsinks
External Electrical
Wiring
External Solder
Connections
Dirt and moisture
buildup
Front panel controls
and meters
Looseness, bent or corroded
contacts, damage or improper
seating in mating connector
Dirt and Corrosion
Broken, burned or pinched
wire; frayed, worn or missing
insulation
Corrosion, loose, cracked, or
dirty connections
Short circuits, arcing, corrosion,
overheating
Dirt and corrosion
Clean contacts with solvent
moistened cloth, soft bristle brush,
small vacuum or low compressed
air.
Replace connectors damaged,
deeply corroded, or improperly
seated in mating connector.
Clean with cloth moistened with
soapy water.
Repair or replace defective wires.
Clean and resolder connections.
Clean as required.
Clean with cloth moistened with
soapy water.
Use a Kimwipe tissue and GTC
glass cleaning compound to clean
the meter faces.
M550001-01
5-2
Содержание D3 Series
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 25: ...Figure 2 4 P83 Outline Drawing 5 0KW to 15KW Output Voltage 80 V POWER VOLTAGE CURRENT M550001 01 2 9 ...
Страница 26: ...Figure 2 5 P66 Outline Drawing 13 3KW to 20kW Output Voltage 60 V M550001 01 2 10 POWER VOLTAGE CURRENT ...
Страница 27: ...Figure 2 6 P86 Outline Drawing 20KW to 30KW Output Voltage 80 V M550001 01 2 11 POWER VOLTAGE CURRENT ...
Страница 28: ...This page intentionally left blank M550001 01 2 12 ...
Страница 44: ...This page intentionally left blank M550001 01 3 16 ...
Страница 56: ...INPUT FILTER CONVERTER ASSEMBLY CONTROL ASSEMBLY Figure 4 1 P62 Internal Layout M550001 01 4 12 ...
Страница 59: ...Figure 4 4 P83 P86 Internal Layout M550001 01 4 15 ...
Страница 60: ...Figure 4 5 P83 P86 Converter Card M550001 01 4 16 ...
Страница 61: ...Figure 4 6 P63 P66 Converter Card M550001 01 4 17 ...
Страница 62: ...This page intentionally left blank M550001 01 4 18 ...