Press and hold learn button on the receiver box
for 10 seconds.
PR-2
14
INSTRUCTIONS PL300E/PL400E/PL500E/PL800E SLIDING GATE OPENER USER MANUAL
34100-095-15-C
Output 1 operation
LED Light
Output 2 operation
Single-gate
operation
gate openers
Dual-gate
operation
gate openers
4. Memory Erasing
Please refer to figure 5.2.1
5. 4 Channel Transmitter Operation
Figure 5.2.1
A
B
C
D
OFF
ON
Green Box
5+
Cable
AC out
AC in
5.3 Green Box Installation Guide
Green Box is for purpose when gate opener is in standby mode to allow it enter the power saving mode.
Installation manner:
AC IN: connect the electricity
AC OUT: connect the power of gate opener, and connect the transformer
5V CABLE: connect 3 pins white socket of control board
Please make sure the switch of Green Box is off before proceeding the system learning and installation of device. Wait
for the system learning and installation of device to be completed, power on the Green Box
Gate opener will enter power saving mode without receiving any instruction in 1 min, and red LED light on Green Box
will be activated. Gate opener start the operation, red LED light and power saving mode will turn off.
CAUTION: