background image

Smart Roller Shutter

Slat Shutter Door Opener

WARNING:

  IT  IS  VITAL  FOR  THE  SAFETY  OF  ALL 

PERSONS  INSTALLING AND  USING  THIS  OPENER  TO 

FOLLOW  THE  INSTALLATION  INSTRUCTIONS  AND 

SAFETY WARNINGS. FAILURE TO COMPLY MAY RESULT 

IN  SERIOUS  PERSONAL  INJURY  AND/OR  PROPERTY 

DAMAGE AND FAILURE OF THE OPENER SYSTEM.

INSTALLATION MANUAL

Summary of Contents for Smart Roller Shutter

Page 1: ... VITAL FOR THE SAFETY OF ALL PERSONS INSTALLING AND USING THIS OPENER TO FOLLOW THE INSTALLATION INSTRUCTIONS AND SAFETY WARNINGS FAILURE TO COMPLY MAY RESULT IN SERIOUS PERSONAL INJURY AND OR PROPERTY DAMAGE AND FAILURE OF THE OPENER SYSTEM INSTALLATION MANUAL ...

Page 2: ...l Specifications Warranty 3 3 3 4 5 8 8 9 10 11 11 11 12 12 12 13 13 14 14 14 15 15 15 15 15 16 To the extent that they may be lawfully excluded Smart Openers Pty Ltd hereby expressly excludes all conditions and warranties statutory or otherwise which may be implied by law as conditions or warranties of purchase of a Smart Openers Pty Ltd Door Opener Smart Openers Pty Ltd hereby further disclaims ...

Page 3: ...ether directly or indirectly from failure to install the system correctly and in accordance with the relevant safety standards and installation manual For a more detailed list of the Safety Warnings and safety issues associated with the installation and use of a Smart Roller Shutter Opener refer to the safety warnings in the OWNERS MANUAL No Package Part 1 Motor No Description Qty 1 Motor 1 Set 2 ...

Page 4: ...e magnetic lock 14 Connector for DC flashing light or similar 5A max 15 Connector for DC courtesy light or similar 5A max 16 Connector for solar panel or external DC charger 17 Connector for controller power from transformer 1 2 3 4 5 6 7 8 Com Push Btn Pedestrian Stop Close Open M2 Open Limit Com M2 Close Limit M1 Open Limit Com M1 Close Limit Com Photo Beam 2 Photo Beam 1 24V Lock Lock Activity ...

Page 5: ...otection against short circuits power spikes and proper earthing on the mains supply Remember the unit has mains voltage running through it electrocution hazard fire hazard etc 4 Take care with the control unit parts may be subject to damage if abused 5 Make sure you have all the necessary materials and that they are suitable for this kind of use 6 Read all the instructions thoroughly and make sur...

Page 6: ...t shaft and the wall If the situation permits it is recommended that 300mm is allowed Left Hand Right Hand Installation The Smart Roller Shutter Opener has been factory preset to the right hand side as per Fig 1a If this is correct for your installation no changes need to be made to the opener To change to left hand side the following modifications need to be made 1 Remove screws and swap the posi...

Page 7: ...access to the door before that repair is made 1 Ensure that the existing door bracket is suitable to have an opener fitted If not fit an appropriate bracket or use the mounting plate supplied with the opener Note The mounting plate must be fitted to a solid fixture The mounting holes in the plate are slotted for fine adjustment to achieve appropriate tension on the drive chain 2 Fix the mounting p...

Page 8: ...uide Use the table below as a reference to guide you through the menu system and parameters Fig 6 Motor Connector Cable Open Switch Dead man Close Switch Emergency Stop Switch Power Cable Isolation Lock Battery Back Up Menu Item Factory Default Options 1 Pedestrian Mode On On Off 2 Lock Pulse Pulse Hold Magnetic 3 Obstruction Setting 03 00 09 4 Open Speed 80 50 100 by 5 5 Close Speed 80 50 100 by ...

Page 9: ...to the next menu item l Pressing MODE at any time will store changes and exit to main screen To enter limits set up press SET To enter parameter settings press MENU Setting Motor Installation 1 Press SET for 3 secs to enter set up The display will show Right Hand Installation default Fig 10 If this is correct when standing inside looking out press SET to confirm Option To change to Left Hand Fig 1...

Page 10: ...on Set for 2 secs 7 The drive motor will now run through a full cycle to measure time current and force margin required to open and close Note If pedestrian mode is enabled the display will show Set Ped Position Fig 16 indicating that the Pedestrian Open Position can now be set Otherwise the display will show Set Up Complete Setting Pedestrian Mode Pedestrian Mode allows the door to open partially...

Page 11: ...low the door to travel without phantom reversing is used Smart Openers strongly recommend that the door is properly serviced rather than increasing the force margin to compensate Factory Default 03 1 Press MENU for 3 secs then press SET to cycle through to Obstruction Margin 2 Press MENU to cycle through from 01 very sensitive 09 least sensitive 3 Press SET to confirm and move to next item or pres...

Page 12: ...lectric safety beam must be installed and Photo Beam Mode set to ON to enable auto close function Photo Beam Mode allows the door to close once the beam has been tripped and restored Smart Openers strongly recommend the installation of a PE safety beam to protect persons and property Factory Default Off 1 Connect PE beam cable to controller terminal black as per Fig 21 2 Press MENU for 3 secs then...

Page 13: ...are tripped 1 Make sure that a functioning PE beam is connected and Photo Beam Mode is set to On as per Page 11 2 Press MENU for 3 secs then press SET to cycle through to Auto Close or PE Close or Sequence Mode 3 Press MENU to choose On 4 Press SET to confirm and move to next item or press MODE to exit to normal operation Setting Auto Close Timer Delay Auto Close Time delay is used with Auto Close...

Page 14: ...te 023 3 Press and hold CODE for 3 secs to confirm The stored code has now been deleted Replacing One Transmitter 1 Press CODE The LCD will display Code Learn 2 Press transmitter button once the LCD will display the previously deleted number e g Remote 023 Press Button again to confirm Deleting All Transmitters 1 Press and hold CODE for 5 seconds The LCD will display Del Remote All 2 Press and hol...

Page 15: ...dition IMPORTANT A poorly operating door can effect the life of the automatic opener due to incorrect loads and will void the warranty Check the reversing sensitivity at least twice a year and adjust if necessary Make sure that the safety devices are working effectively photo beams etc Final Notes This manual is only for use by technical personnel qualified to carry out the installation No informa...

Page 16: ... unauthorised repairs g any cost relating to damage caused deliberately or by misuse negligence or failure to maintain the equipment in a proper working order including without limitation due to anything described in paragraphs d and e h installation adjustment or use which is not in accordance with the instructions set out in installation instruction manual and owners manual i attempted or comple...

Reviews: