34100-124-01-C
6. Maintenance
Conduct the following operations at least every 6 months. If in high intensity of use, shorten the period in between.
Disconnect the power supply:
(1) Clean and lubricate the screws, the pins, and the hinge with grease.
(2) Check the fastening points are properly tightened.
(3) Make the wire connection are in good condition.
Connect the power supply:
(1) Check the power adjustments.
(2) Check the function of the manual release.
(3) Check the function of photocells or other safety devise.
5.2 Technical Feature:
Model
Motor
Gear type
Nominal thrust
Maximum Gate Weight
Maximum Gate Length
Operating Temperature
Dimension
Weight
PA250
24Vdc motor
Electromechanical worm gear
2500N
250 kg per leaf
2.5 meters per leaf
-20
o
C~+50
o
C
256 x 187 x 267mm
6 kg
Model
Main power supply
Back-up battery
Receiver board
Installation
Operating Temperature
Dimension
PC190
230Vac/110Vac, 50Hz/60Hz
2pcs of batteries for emergency operation, 1.2A each
433.92MHz; 200 transmitters memory
Built - in PCBA
-20
o
C~+50
o
C
275mm x 195mm x 102mm