ARTICULATED ARM OPENERS USER MANUAL
12
2.5 Gate Operation
Press the button “A” on the transmitter for dual-gate operation.
Press the button “B” on the transmitter for single-gate
operation in either single-gate or dual-gate installation.
2.6 Gate-moving Logic
(A) In gate-opening phase: The gates stop if the transmitter/push button/key selector is activated, and close when
the transmitter/push button/key selector is reactivated.
(B) In gate-closing phase: The gates stop if the transmitter/push button/key selector is activated, and open when
the transmitter/push button/key selector is reactivated.
(C) In gate-opening or gate-closing phase: For safety purpose, the gates stop if encountering obstacles.
2.7 Checking the Gate Movement
1). Release the gearmotor with the release key and move the gate to the middle so that it is free to move in both
opening and closing directions; then lock the gearmotor.
2). Perform the gate opening and closing several times and make sure the gates reaches the limit switch at least
2~3 centimeters before the mechanical stop.
3.1 Function Of The Led Display
3. Function Setting
LED Display
Programmable Functions
“N-L”: The system learning is not done.
“RUN”: The system is in normal performing.
“CLN” The memory of the system is all cleaned/deleted. Press and hold “UP+DOWN” for
5 seconds.
“STP”: The motor stop in the middle of the operating process.
“ME”: Motor operation error
“LEA”: Enter learning mode and then wait for learning instructions.
The operation of gate learning:
(1). Press “SET” + “DOWN” + “UP” for 3seconds, and the LED display shows “LEA” +”DG”;
and then press the transmitter (A) button one time. After 1~3seconds, the LED display shows
the current value during learning mode, it shows 10 for 1A.
A
B
C
D