6

SAFETY INFORMATION:

DANGER OF CHEMICAL BURNS! Protect your eyes and skin 
against chemical burns caused by acid (sulphuric acid) upon 
contact with the battery! 

Wear: Acid-resistant glasses, clothing and gloves! If your eyes or 
skin come into contact with sulphuric acid, rinse the affected part 
of the body with plenty of clear running water and seek immediate 
medical assistance!

• 

Avoid causing an electrical short-circuit when connecting the battery 
charger to the battery. Connect the minus pole connecting cable only to 
the minus pole of the battery or to the car body. Connect the plus pole 
connecting cable only to the plus pole of the battery!

• 

Before connecting to the mains, make sure that the mains current is 
equipped with standard 230 V ~ 50 Hz, PEN conductor, a 16 A fuse and a 
residual-current circuit-breaker! Otherwise the device could be damaged.

• 

Do not place the battery charger near fire, heat, or subject it to prolonged 
temperatures of over 50 °C! The output from the battery charger drops 
automatically in high temperatures.

• 

Avoid damaging any lines carrying fuel, electricity, brake fluid, hydraulic oil or 
water. Be particularly careful not to cause damage when mounting the charger 
in place with screws! Failure to observe this advice risks loss of life or injury!

• 

Use only the supplied original manufacturer’s parts with the battery charger!

• 

Do not allow any objects to cover the battery charger! Otherwise the device 
could be damaged.

• 

Protect the electrical contacts of the battery against short-circuiting!

• 

Use the battery charger only for charging and maintenance charging of 
undamaged 6 V / 12 V lead batteries (wet cell or gel electrolyte)! Otherwise 
damage to property could occur.

• 

Do not use the battery charger for charging or maintenance charging of 
disposable batteries. Otherwise damage to property could occur.

• 

Do not use the battery charger for charging or maintenance charging of 
damaged or frozen batteries! Otherwise damage to property could occur.

• 

Before connecting the charging station, read the information on battery 
maintenance in the operating instructions of the battery! Otherwise personal 
injury and / or damage to the device could occur.

• 

Before connecting the charging station to a battery permanently installed 
in a vehicle, read the information on electrical safety and maintenance in 
the operating instructions of the vehicle! Otherwise personal injury and / or 
damage to the device could occur.

• 

Unplug the charger from the mains supply when not being used! This also 
benefits the environment. Consider how much electricity is consumed, even 
in standby mode.

• 

Remain alert at all times and always watch what you are doing. Always 
proceed with caution and do not use the battery charger if you cannot 
concentrate or feel unwell.

• 

Do not charge non-rechargeable batteries

• 

Max. operation temperature: 40ºC

Содержание MB3908

Страница 1: ...Instruction Manual 10 Step Bluetooth Intelligent Lead Acid and Lithium Battery Charger MB3908...

Страница 2: ......

Страница 3: ...ion 9 Disconnecting 9 Select Charging Mode 9 Memory Function Reset 10 Switching Between Modes 10 Automatic Detection of Battery 11 Recover 12V Mode 12 12V Automotive Lead acid Battery Mode 12 24V Truc...

Страница 4: ...of 10 80 Ah You can also used it to regenerate completely discharged batteries The battery charger has protective circuits to prevent sparking and overheating Any incorrect or improper use leads to lo...

Страница 5: ...Power Supply 13 6V 5 0A 9 Mode 7 LITHIUM 12 8V 12 8V 4 cells LiFePO4 5 0A A Charging battery level 1 bar 20 2 bars 40 3 bars 60 4 bars 80 5 bars 90 Stops flashing fully charged B VOLT The current volt...

Страница 6: ...MPS Charging current 7 5 A 10 3 75 A 10 5 0 A 10 Battery type 12V lead acid battery 18Ah 240Ah 24V lead acid battery 10 Ah 120Ah Lithium 12 8V 4 cells LiFePO4 with a capacity of 10 80Ah Housing protec...

Страница 7: ...ect the positive clamp to the positive terminal of the battery then connect the other clamp to the vehicle chassis at a point away from the battery and the fuel line After this is done you can connect...

Страница 8: ...Oxyhydrogen gas is an explosive mixture of gaseous hydrogen and oxygen The result is the so called oxyhydrogen reaction upon contact with open fire flames embers or sparks Carry out the charging or di...

Страница 9: ...turer s parts with the battery charger Do not allow any objects to cover the battery charger Otherwise the device could be damaged Protect the electrical contacts of the battery against short circuiti...

Страница 10: ...ase charging strategy as follows Step 1 Check Checks the battery voltage to make sure battery connections are good and the battery is in a stable condition before beginning the charge process Step 2 R...

Страница 11: ...tage falls below 12 8V 12V and 25 6V 24V the charger will start the Maintenance cycle until voltage reaches 13 6V 12V and 27 2V 24V and then discontinues the charge cycle The cycle between Trickle and...

Страница 12: ...peratures In comparison with conventional battery charging stations this appliance has a special function for reusing an empty battery or rechargeable battery You can recharge an empty battery recharg...

Страница 13: ...then repeats the cycle The device switches between charging modes in the following order for 24V battery Standby MODE 1 MODE 1 3 and then repeats the cycle Long press 3 sec the MODE selection button t...

Страница 14: ...capacity has been reached the charging current is reduced This ensures a gentle and best possible charging up to the battery s maximum capacity 12 V Battery If the battery voltage is between 2 0 and...

Страница 15: ...and will stop flashing The device now switches automatically into maintenance charging mode The battery voltage has not risen to 12V after 3 hours The error message appears and flashing on the display...

Страница 16: ...fully charged the battery icon should be full and will stop flashing The device now switches automatically into maintenance charging mode Long press 3sec the MODE selection button if the measured vol...

Страница 17: ...sh at with a current of 7 5A If the process runs without any problems the LCD display will show the battery charging bars will start flashing until the battery is charged When the battery is fully cha...

Страница 18: ...ose 6V Mode Motorcycle or Car Mode 9 You may also choose Cold mode for cold environment or Recover mode for depleted battery 10 You may opt to input ON OFF command to stop charging or to proceed with...

Страница 19: ...16 MOBILE APPLICATION USER INTERFACE...

Страница 20: ...17 MOBILE APPLICATION USER INTERFACE...

Страница 21: ...rk Danger of electrocution Never immerse the charger in water as entering water can damage the charger When necessary clean charger with a soft dry lint free cloth Only when heavily soiled use a damp...

Страница 22: ...19...

Страница 23: ...20...

Страница 24: ...Made in China...

Отзывы: