RECOVER 12V MODE (14.7V 7.5A): REACTIVATION OF  
DEEP-DISCHARGED 12 V BATTERIES USING PULSE CHARGING

This mode is mainly suitable for charging 12 V lead-acid batteries with a 
capacity greater than 18 Ah. Long press 3 sec. the MODE selection button, if 
the measured voltage is between 2.0 V and 14 V the battery is identified as a 
12V battery to activate 

RECOVER 12V

 

mode

.

 

Then if you do not take any further action, the electronic system will 
automatically start the charging process together with the LCD display will 
flash at (with a current of) 2.6A.  If the process runs without any problems, 
the LCD display will show the battery charging (bars will start flashing) until 
the battery is charged. When the battery is fully charged, the battery icon 
should be full and will stop flashing. The device now switches automatically 
into maintenance charging mode. The battery voltage has not risen to 12V 
after 3 hours, The error message 

 appears and flashing on the display 

and returning to the standby mode. 

 OR 

 

 

MODES (14.5V 7.5A / 14.7V 7.5A):

This mode is mainly suitable for charging 12V lead-acid batteries with a 
capacity greater than 18 Ah.

Press the MODE selection button to select MODE 

 or 

 

.  

After doing so, the corresponding LCD display 

 or 

 

 lights up.

Then if you do not take any further action, the electronic system will 
automatically start the charging process together with the LCD display will 
flash at (with a current of) 7.5A.  If the process runs without any problems, 
the LCD display will show the battery charging (bars will start flashing) until 
the battery is charged. When the battery is fully charged, the battery icon 
should be full and will stop flashing. The device now switches automatically 
into maintenance charging mode.

Содержание MB3908

Страница 1: ...Instruction Manual 10 Step Bluetooth Intelligent Lead Acid and Lithium Battery Charger MB3908...

Страница 2: ......

Страница 3: ...ion 9 Disconnecting 9 Select Charging Mode 9 Memory Function Reset 10 Switching Between Modes 10 Automatic Detection of Battery 11 Recover 12V Mode 12 12V Automotive Lead acid Battery Mode 12 24V Truc...

Страница 4: ...of 10 80 Ah You can also used it to regenerate completely discharged batteries The battery charger has protective circuits to prevent sparking and overheating Any incorrect or improper use leads to lo...

Страница 5: ...Power Supply 13 6V 5 0A 9 Mode 7 LITHIUM 12 8V 12 8V 4 cells LiFePO4 5 0A A Charging battery level 1 bar 20 2 bars 40 3 bars 60 4 bars 80 5 bars 90 Stops flashing fully charged B VOLT The current volt...

Страница 6: ...MPS Charging current 7 5 A 10 3 75 A 10 5 0 A 10 Battery type 12V lead acid battery 18Ah 240Ah 24V lead acid battery 10 Ah 120Ah Lithium 12 8V 4 cells LiFePO4 with a capacity of 10 80Ah Housing protec...

Страница 7: ...ect the positive clamp to the positive terminal of the battery then connect the other clamp to the vehicle chassis at a point away from the battery and the fuel line After this is done you can connect...

Страница 8: ...Oxyhydrogen gas is an explosive mixture of gaseous hydrogen and oxygen The result is the so called oxyhydrogen reaction upon contact with open fire flames embers or sparks Carry out the charging or di...

Страница 9: ...turer s parts with the battery charger Do not allow any objects to cover the battery charger Otherwise the device could be damaged Protect the electrical contacts of the battery against short circuiti...

Страница 10: ...ase charging strategy as follows Step 1 Check Checks the battery voltage to make sure battery connections are good and the battery is in a stable condition before beginning the charge process Step 2 R...

Страница 11: ...tage falls below 12 8V 12V and 25 6V 24V the charger will start the Maintenance cycle until voltage reaches 13 6V 12V and 27 2V 24V and then discontinues the charge cycle The cycle between Trickle and...

Страница 12: ...peratures In comparison with conventional battery charging stations this appliance has a special function for reusing an empty battery or rechargeable battery You can recharge an empty battery recharg...

Страница 13: ...then repeats the cycle The device switches between charging modes in the following order for 24V battery Standby MODE 1 MODE 1 3 and then repeats the cycle Long press 3 sec the MODE selection button t...

Страница 14: ...capacity has been reached the charging current is reduced This ensures a gentle and best possible charging up to the battery s maximum capacity 12 V Battery If the battery voltage is between 2 0 and...

Страница 15: ...and will stop flashing The device now switches automatically into maintenance charging mode The battery voltage has not risen to 12V after 3 hours The error message appears and flashing on the display...

Страница 16: ...fully charged the battery icon should be full and will stop flashing The device now switches automatically into maintenance charging mode Long press 3sec the MODE selection button if the measured vol...

Страница 17: ...sh at with a current of 7 5A If the process runs without any problems the LCD display will show the battery charging bars will start flashing until the battery is charged When the battery is fully cha...

Страница 18: ...ose 6V Mode Motorcycle or Car Mode 9 You may also choose Cold mode for cold environment or Recover mode for depleted battery 10 You may opt to input ON OFF command to stop charging or to proceed with...

Страница 19: ...16 MOBILE APPLICATION USER INTERFACE...

Страница 20: ...17 MOBILE APPLICATION USER INTERFACE...

Страница 21: ...rk Danger of electrocution Never immerse the charger in water as entering water can damage the charger When necessary clean charger with a soft dry lint free cloth Only when heavily soiled use a damp...

Страница 22: ...19...

Страница 23: ...20...

Страница 24: ...Made in China...

Отзывы: