32
Trouble Probable
Cause
Remedy
Miswiring of the unit.
Double check to confirm all electrical
connections are correct. Refer to
appropriate wiring diagrams on pages
44 through 46 to make any needed
corrections.
Machine will not
start/restart or
repeatedly trips
circuit breaker or
blows fuses.
On/off switch failure.
If the on/off switch is suspect, you
have two options: Have a qualified
electrician test the switch for function,
or purchase a new on/off switch and
establish if that was the problem on
changeout.
Optional Accessories
6296046 .......... Knives (set of 3)
2230035 .......... Knife Setting Gauge
6285917 .......... Push Block
Replacement Parts
Replacement parts are listed on the following pages. To order parts or reach our service department, call
1-800-274-6848 between 7:30 a.m. and 6:00 p.m. (CST), Monday through Friday. Having the Model
Number and Serial Number of your machine available when you call will allow us to serve you quickly and
accurately.
Содержание PJ-882
Страница 35: ...35 Fence Assembly ...
Страница 37: ...37 Outfeed Table and Base Assembly ...
Страница 40: ...40 Infeed Table Assembly ...
Страница 43: ...43 Stand Assembly ...
Страница 44: ...44 Electrical Connections 1 Phase 230 Volt ...
Страница 45: ...45 Electrical Connections 3 Phase 230 Volt ...
Страница 46: ...46 Electrical Connections 3 Phase 460 Volt ...
Страница 47: ...47 ...
Страница 48: ...48 WMH Tool Group 2420 Vantage Drive Elgin Illinois 60123 Phone 800 274 6848 www wmhtoolgroup com ...