If you are hard-wiring the Jointer, make sure the
fuses have been removed or the breakers have
been tripped in the circuit to which the Jointer
will be connected, and place a warning placard
on the fuse holder or circuit breaker to prevent it
being turned on until wiring is complete.
Converting from 230 Volt to 460 Volt
(Three Phase Only)
Refer to the diagram on page 46 for connecting
the motor leads for 460 volt power. If using a
plug, it must be a proper UL/CSA listed plug
suitable for 460 volt operation. The Jointer must
comply with all local and national codes after
being wired.
Three-Phase Test Run
On the three-phase unit, after wiring has been
completed, you should check that the wires
have been connected properly:
1. Connect machine to power source and
press the start button, shown in Figure 10.
(See “Operating Controls” on page 24 for
further information on the control switch.)
2. The cutterhead should rotate clockwise as
viewed from the front of the machine. If the
cutterhead rotation is incorrect, press the
stop button (Figure 10) and disconnect
machine from power.
3. Switch any two of the three wires at "R,S,T".
4. Reconnect machine to power source.
Adjustments
Drive Belt Tension
To check or adjust the drive belt tension:
1. Unscrew the knob (A, Figure 11) and
remove the belt guard (B, Figure 11).
2. Remove the rear panel (C, Figure 11) by
unscrewing the four flat head screws (D,
Figure 11) with a cross-point screwdriver.
3. Proper drive belt tension is achieved when
there is a small amount of deflection in the
drive belt midway between the pulleys,
when using moderate finger pressure
(Figure 12).
4. To increase the tension on the drive belt,
loosen the lower hex nut (B, Figure 13) with
a 17mm wrench, and tighten the top hex nut
(A, Figure 13). When finished, tighten lower
hex nut (B, Figure 13).
5. Re-install rear panel and belt guard.
Figure 10
Figure 11
Figure 12
Figure 13
Содержание PJ-882
Страница 35: ...35 Fence Assembly ...
Страница 37: ...37 Outfeed Table and Base Assembly ...
Страница 40: ...40 Infeed Table Assembly ...
Страница 43: ...43 Stand Assembly ...
Страница 44: ...44 Electrical Connections 1 Phase 230 Volt ...
Страница 45: ...45 Electrical Connections 3 Phase 230 Volt ...
Страница 46: ...46 Electrical Connections 3 Phase 460 Volt ...
Страница 47: ...47 ...
Страница 48: ...48 WMH Tool Group 2420 Vantage Drive Elgin Illinois 60123 Phone 800 274 6848 www wmhtoolgroup com ...