Powermaster Model RSG 2000

 

INSTALLATION MANUAL 

 

CAREFULLY READ THIS ENTIRE MANUAL FIRST BEFORE PROCEEDING! 

 

LEAVE THIS MANUAL WITH END USER FOR FUTURE REFERENCE AFTER INSTALLATION IS COMPLETE 

(LAST PAGE SHOULD BE FILLED OUT AND RETAINED BY INSTALLER FOR FUTURE USE) 

 

THE FOLLOWING INFORMATION SHOULD BE RECORDED AT TIME OF INSTALLATION: 

 

 
Date: ____________  Serial #:__________________________  Wiring Diagram #:___________________ 
 
THE OPERATOR SERIAL # IS LOCATED ON THE REAR INTERIOR WALL OF THE OPERATOR 
ENCLOSURE. THE WIRING DIAGRAM IS LOCATED IN THE LEFT INTERIOR WALL OF THE 
OPERATOR ENCLOSURE WITH THE DIAGRAM # AT THE LOWER RIGHT- HAND CORNER OF 
PAGE. 
 
THE ABOVE INFORMATION SHOULD BE GIVEN IN ALL CORRESPONDENCE REGARDING 
THE OPERATOR TO INSURE FAST SERVICE WHEN ORDERING PARTS OR REQUESTING 
INFORMATION. 
 
The above identified unit is rated in the following class: 
 
[ X ] Class I- Residential Vehicular Gate Operator -A vehicular gate operator (or system) intended for use 
in a home of one to four single family dwellings, or a garage or parking area associated therewith.  
[ X ] Class II- Commercial/General Access Vehicular Gate Operator -A vehicular gate operator (or system) 
intended for use in a commercial location or building such as a multifamily housing unit (five or more 
single family units), hotel, garages, retail store or other building servicing the general public.  
[ X ] Class III- industrial/limited Access Vehicular Gate Operator -A vehicular gate operator (or system) 
intended for use in an industrial location or building such as a factory or loading dock area or other 
locations not intended to service the general public.  
[ X ] Class IV Restricted Access Vehicular Gate Operator -A vehicular gate operator (or system) intended 
for use in a guarded industrial location or building such as an airport area or other restricted access locations 
not servicing the general public, in which unauthorized access is prevented via supervision by security 
personnel. 
 
Attach large warning signs provided to each side of gate in the most conspicuous place. Mount control 
station and smaller warning placard together within sight of the gate opening. 

Attach large warning signs 
provided to each side of gate in 
the most conspicuous place. 
Mount control station and smaller 
warning placard together within 
sight of the gate opening. 

Содержание RSG 2000

Страница 1: ...herewith X Class II Commercial General Access Vehicular Gate Operator A vehicular gate operator or system intended for use in a commercial location or building such as a multifamily housing unit five...

Страница 2: ...er to ensure that the total system is safe for its intended use All secondary entrapment safety devices must be U L recognized to complete the operating system SYSTEM DESIGNER SAFETY INSTRUCTIONS 1 Fa...

Страница 3: ...the automatic controls do not work Locate the push button or key switch and small warning placard within sight of gate in a secured area at least 10 feet or more from the gate and fence to keep users...

Страница 4: ...e sure roller guards have been purchased and installed 7 Your gate system is required to have a primary and a secondary entrapment safety system installed and maintained See page 7 8 8 If your gate cl...

Страница 5: ...caught between the grille and the fence post or fence The potential hazard must be guarded It can be simply done by placing a screen mesh on the gate and fence in the area of the gate The screen must...

Страница 6: ...d cementing of mounting posts minimum of 2 deep 3 Set mounting posts and electrical conduits in place 4 Pour cement to secure mounting posts and let cure for two days prior to operator installation No...

Страница 7: ...ocket See Figs 3 6 8 Pull drive chain though to opposite end of gate cut to correct length and secure to gate bracket using 3 8 inch chain take up bolt as done in steps 4 and 5 Note When pulling drive...

Страница 8: ...ntacts must be NORMALLY OPEN Connect STOP button to terminal 4 Connect COMMON button to terminal 5 Connect OPEN button to terminal 6 Connect CLOSE to terminal 7 PRIMARY OBSTRUCTION SENSING DEVICE Note...

Страница 9: ...te Install photoelectric cell as close to inside of gate as possible Note Photo cells should be installed across gate opening and behind gate See Fig 11 at least 10 inches above ground 1 After sensors...

Страница 10: ...adio s installation manual to determine which wires are for the normally open contacts and which require the 24 VAC power supply TIMER TO CLOSE The operator is equipped with a timer to close option fo...

Страница 11: ...wrong turn off main power and recheck drive chain installation See Fig 4 6 If drive chain is correct consult the factory WARNING UNDER NO CIRCUMSTANCES SHOULD CONTROL STATION WIRING BE ALTERED IF ROTA...

Страница 12: ...ENTRY Open only 1 Connect MO to terminal 3 2 Connect common to terminal 5 DO NOT Connect N O to terminal 6 FIG 6 EXIT LOOP Open only 1 Connect common yellow to terminal 3 2 Connect N O blue to termina...

Страница 13: ...13...

Отзывы: