Environmental Specifications
VAC
Specification
Operating Temperature*
-40 C to +85 C (screen not visible below -32 C)
Storage Temperature*
-40 C to +85 C
Humidity
MIL-STD-810F, Method 507.4, 95% RH (non-condensing)
Environmental Sealing
Exceeds NEMA 3R, Mil-Std-810E Method 506.3 Procedure III; IP67
Vibration
MIL-STD-810F, Method 514.5 (12.35Grms random vibration), heavy duty truck chassis mount
Shock
MIL-STD-810F, Method 516.5, Procedure I (20 G Functional), V (40 G Crash Hazard)
Drop (product)
3 ft onto Concrete; 1 per side
Altitude
MIL-STD-810F, Method 500.4, Section II (Operations/Air Carriage)
– 15,000 ft
Solar
MIL-STD-810F, Method 505.4, Procedure II (Cyclic)
Thermal Shock
MIL-STD-810F, Method 503.4, Procedure II (Cyclic), -
40C ↔ +70C
Salt Fog
MIL-STD-810F, Method 509.4
ESD
+/- 8kV contact; +/- 15kV non-contact
* Prolonged exposure to temperatures above 70° C may affect keypad tactile response.