10HP - 20HP Scroll Enclosure Air Compressors
Pg 3
MAINTANANCE SCHEDULE
Item
Action Needed
Operating Hours
500
2500
5000
10,000
20,000
Remarks
Intake Filter
Replace
Every 2500 hours or less
Ventilation Screen
Clean
Every 500 hours or less
Air End/Blower Fan
Clean
Every 5000 hours or less
Fan Duct
Clean
Every 5000 hours or less
Compressor Fins
Clean
Every 2500 hours or less
Compressor
Grease
Use genuine Powerex grease
(every 5000 hours for High
Pressure Models)
Tip Seal
Replace
(every 5000 hours for High
Pressure Models)
Dust Seal
Inspect, Replace
(every 5000 hours for High
Pressure Models)
V-belt
Inspect, Replace
*
*Readjust
Pressure Sensor
Confirm
Operation
Check touchscreen for pressure rise
and fall
Magnetic Starter
Inspect
Replace if contact points are
deteriorated/excessive arching
Check Valve
Inspect
Confirm operation by watching pump
and motor shut off and stop turning
Safety Valve
Confirm
Operation
Every 500 hours or less. Pull ring to
make sure not stuck or plugged.
Ventilation Fan
Inspect
Confirm ventilation air is exiting
Motor Pulley
Inspect Groove/
Make sure tight
on shaft
Replace if abnormal wear is detected
Motor
Inspect
Replace if abnormal noise is
detected./ Make sure electrical
connections are secure.
Intake Hose
Inspect
Replace if damaged or deteriorating
Braided Hose
Inspect, Replace
Make sure there are no leaks
Aftercooler
Clean outside
Every 5000 hours or less
Operating Panel
Inspect monitor
daily
Verify pressure/Check for alarm
notification
Piping
Inspect for leaks
Every 2500 hours or less
NOTES:
1. Inspect and perform maintenance periodically according to the maintenance schedule.
2. The maintenance schedule relates to the normal operating conditions. If the circumstances and load condition are adverse,
shorten the cycle time and perform maintenance accordingly.
3. *Marked “Readjust” means the tension of the V-belt should be adjusted during the initial stage and inspected every 2,500
hours afterwards.
Inspect
Replace
Replace Pump