background image

Med Touch Series LCD Alarm Systems

Powerex  

  150 Production Drive  

  Harrison, OH  45030  

  USA

P   1.888.769.7979  

  F   513.367.3125  

  www.powerexinc.com

IN597400AV  

  08/2016

Page 56 of 56

(a) 

Powerex will not accept and shall have no responsibility for products returned without its prior written consent, and 

(b)

 Powerex will not 

assume any expense or liability for repairs to products made outside of its plant by third parties. In the event Powerex elects to replace a 

defective product, costs of installation, labor, service, and all other costs to replace the product shall be the responsibility of Buyer.

Powerex shall not, except as set forth above, be otherwise liable to Buyer or to any person who shall purchase from Buyer, or use, any products 

supplied hereunder for damages of any kind, including, but not limited to, indirect, special or consequential damages or loss of production of 

loss of profits resulting from any cause whatsoever, including, but not limited to, any delay, act, error or omission of Powerex. Supplier’s repair 

or replacement of any Product shall not extend the period of any warranty of any Product.

Warranty Disclaimer.

 Powerex has made a diligent effort to illustrate and describe the Products in its literature, including its Price Book, 

accurately; however, such illustrations and descriptions are for the sole purpose of identification, and do not express or imply a warranty that 

the Products are merchantable, or fit for a particular purpose, or that the Products will necessarily conform to the illustrations or descriptions.

Product  Suitability.

  Many  jurisdictions  have  codes  and  regulations  governing  sales,  construction,  installation,  and/or  use  of  Products  for 

certain purposes, which may vary from those in neighboring areas. While Powerex attempts to assure that its Products comply with such codes, 

it cannot guarantee compliance, and cannot be responsible for how the product is installed or used. Before purchase and use of a Product, 

please review the Product applications, and national and local codes and regulations, and be sure that the Product, installation, and use will 

comply with them.

Claims.

 Any non-warranty claims pertaining to the Products must be filed with Powerex within (6) months of the invoice date, or they will not 

be honored. Prices, discounts, and terms are subject to change without notice or as stipulated in specific Product quotations.  Powerex shall not 

be liable for any delay or failure arising out of acts of the public enemy, fire, flood, or any disaster, labor trouble, riot or disorder, delay in the 

supply of materials or any other cause, whether similar or dissimilar, beyond the control of Company.  All shipments are carefully inspected and 

counted before leaving the factory.  Please inspect carefully any receipt of Products noting any discrepancy or damage on the carrier’s freight bill 

at the time of delivery.  Discrepancies or damage which obviously occurred in transit are the carrier’s responsibility and related claims should be 

made promptly directly to the carrier.  Returned Products will not be accepted without prior written authorization by Powerex and deductions 

from invoices for shortage or damage claims will not be allowed.  

UNLESS OTHERWISE AGREED TO IN WRITING, THE TERMS AND CONDITIONS 

CONTAINED IN THIS LIMITED WARRANTY WILL CONTROL IN ANY TRANSACTION WITH POWEREX.

  Any different or conflicting terms as may 

appear on any order form now or later submitted by the buyer will not control.  All orders are subject to acceptance by Powerex.

Содержание Med Touch Series

Страница 1: ...to 4 transducer sensor inputs 2 85 LCD touch screen displays normal and high low alarm conditions for one 4 20 mA sensor input The LCD touch screen allows all alarm programming and set up to be done...

Страница 2: ...error message will be displayed if incorrect sensor or no sensor is attached Shall be capable of displaying gas readouts PSI kPa BAR inHg or mmHg Gas alarm repeat feature is factory set at 10 minutes...

Страница 3: ...sing the Alarm Program Mode 18 Programming High Low Alarm Pressure Set Points 19 Programming Remote Signal Master Points NO or Disable 19 Programming Remote Signal Master Points NFPA Labels 19 Program...

Страница 4: ...rminal strip for electrical wiring An isolated transformer reduces the 110V or 220V AC input to low voltage DC Front Panel The front panel includes enclosed printed circuit boards with programming cir...

Страница 5: ...the ceiling and eliminates contamination issues such as having to set up a tent in order to remove ceiling tiles Risers DISS x O D tube gas specific risers with our Frontall front loaded check valve a...

Страница 6: ...e contractor is to provide rigid mounting that will support the alarm box on both sides The metal flanges provided on both sides of the rough in box are to rest against the rigid mounting brackets Scr...

Страница 7: ...sure the drop is for the proper gas service Using a purge gas to insure cleanliness in the tubes silver braze the joints Do not use soft solder Conduct heat away from the check valves Per NFPA 99 Chap...

Страница 8: ...etached from the front panel simply snap it back on Attach the two left right side lanyard cables to the alarm back box and if necessary front panel using the screws provided Wiring the Alarm Front Pa...

Страница 9: ...in Appendix F The transducers have been designed so that they may be installed in a standard 4 x 4 x 2 1 8 electrical junction box for added protection A panel mount feature has been provided to allow...

Страница 10: ...on Visually verify that the appropriate transducer wire pair has been attached to the appropriate gas module by looking at the front of the alarm panel If there is not an Error Condition and a System...

Страница 11: ...oints two connection points for each transducer sensor The pairs are labeled 1 IN thru 4 IN on the circuit board The white wire from the transducer should be landed in the WHT position and the black w...

Страница 12: ...Land the 4 20mA signal wire in the Number 2 terminal port Land the ground wire to the Number 3 terminal port For 4 20mA transmitters with loop power supplied by the Alarm Circuit Board 35 0037 Land t...

Страница 13: ...it feeding this alarm panel The toggle switch on the front of the power supply should be placed in the ON position Check the green power LED indicator on the front of the button module It should be il...

Страница 14: ...gnal Transducer Modules The High and or Low Pressure indication will be displayed along with the actual highest or lowest pressure which occurred Remote Signal Master Module If there was an alarm cond...

Страница 15: ...the pressure text box NOTE Alarm settings are maintained even if power is interrupted Units of Measure The Units of Measure is displayed as PSI inHg BAR or kPa whichever is selected during programmin...

Страница 16: ...humidity etc Master dry contact modules will provide up to 8 alarm signals when used in communication with dry contact sensors For each signal point a label must be selected from a pre loaded databas...

Страница 17: ...ces of the medical gas distribution system in communication with the remote equipment dry contacts connected to it and provide the emergency instructions programmed by the user The remote signals mast...

Страница 18: ...d NOTE Only authorized personnel should program the alarm It is important to note that while the panel being programmed is in the program mode it is not monitoring the medical gas system and alarm con...

Страница 19: ...o that the high and low set points must be at least 1 psig in Hg 1 bar or 1 kPa increments apart The high set point will not be able to be set below the low set point and vice versa Re Programming the...

Страница 20: ...acing the board in the program mode and touching the CAL function icon the calibration input screen shown here is displayed The alarm panel has been calibrated and programmed and does not ever require...

Страница 21: ...iew of all of the programming for the circuit board It does not provide any programming options It is simply a view only screen The first line provides the software version The Cal value represents an...

Страница 22: ...how it appears as displayed as part of the gas or transducer master display When an alarm occurs the emergency instructions will appear alternately with the normal information labe NOTE The text will...

Страница 23: ...the numeric value that a 20mA signal will represent i e 2000 gallons These values will represent the span of the 4 20mA device The HIGH and LOW icons are used to set the respective numeric values tha...

Страница 24: ...7 or newer 1 Configure Router Port The port on the router that the Ethernet cable from the Rabbit board will be plugged into must be configured for half duplex Most routers will auto set for this how...

Страница 25: ...werexinc com IN597400AV 08 2016 Page 25 of 56 Create Receive Connector SMTP Simple Mail Transfer Protocol is one of the most common ways of sending e mail SMTP is a simple text conversation across a T...

Страница 26: ...Med Touch Series LCD Alarm Systems Powerex 150 Production Drive Harrison OH 45030 USA P 1 888 769 7979 F 513 367 3125 www powerexinc com IN597400AV 08 2016 Page 26 of 56...

Страница 27: ...ity to bring the laptop close to the alarm panel You will also need a 35 3033 rabbit board programming kit NOTE If your operating system doesn t pull in the driver for the 35 5069 cable you must downl...

Страница 28: ...N597400AV 08 2016 Page 28 of 56 Launch the Real Term Serial Capture Program The set up screen should look like this Under the Display Tab check the Half Duplex Box Under the Port Tab 1 Select a baud r...

Страница 29: ...abbit board or after if a battery was replaced on the rabbit board when the alarm panel was not under 120 VAC power PPN program panel name this command programs the name of the alarm panel as it will...

Страница 30: ...blishes the mail server IP address PUN program user name this command establishes the SMTP user name In the example below we have used powerex wolfcreekmicro com PUP program user password this command...

Страница 31: ...r with the internet the Program Gateway must be used PGW program gateway this command establishes communication from the alarm rabbit board through the facilities network server to the internet Below...

Страница 32: ...ill set the Modbus ID to 1 PDT PROGRAM DATE TIME Usage PDT0129160842 will set RTC to Jan 29th 2016 at 8 42am PDT0203162042 will set rtc to Feb 3rd 2016 at 8 42pm PIP PROGRAM IP Usage PIP192 168 0 50 w...

Страница 33: ...cess Web access to the overview and alarm log pages can be done in several ways Viewing the Website of the Alarms Panels from within your facility ONLY Add the IP address of each rabbit board to your...

Страница 34: ...icking on the Alarm Log button on the left side of the website see above This event log will display up to 100 recent events with the most recent event on the top line and the oldest event on the bott...

Страница 35: ...the plug labeled BLACK Refer to the wiring diagram on the page 55 for proper connections The RS485 data wires blue white and black have been pre wired to the input plug of the 460MMBS gateway Connect...

Страница 36: ...n Page click on Port Configuration It should appear as shown below 2 Enable port 0 and set Mode to RS485 2 wire Half Duplex 3 Set Serial Baud to 9600 Parity None Data Bits 8 and Stop Bits 1 4 Click Sa...

Страница 37: ...map for the largest Powerex alarm panel is embedded in the rabbit board An example of what the Modbus map looks like is shown below The Board ID numbers in the left hand column refer to the boards COM...

Страница 38: ...his will put the gateway into configuration mode so you can edit the BACnet settings 2 Enter the Device instance that the 460MMBS will have on the BACnet IP Network Note that this must be unique among...

Страница 39: ...mmHg 019 PSI or 1 mmHg 039 inHg NFPA National Fire Protection Association The National Fire Protection Association is an association engaged in standards development NO Normally Open An electrical ci...

Страница 40: ...maximum 240 V Pressure Measurement Accuracy 0 30 inHg transducer 1 Vacuum Gas Evacuation 0 100 PSIG transducer 1 Oxygen Nitrous Oxide Medical Air Carbon Dioxide 0 250PSIG transducer 1 Nitrogen Dimens...

Страница 41: ...88 769 7979 F 513 367 3125 www powerexinc com IN597400AV 08 2016 Page 41 of 56 Appendix C Signal Wire Color Code Log Remote Signals Signal Position Remote Signal Label Signal Wire Color Common Wire Co...

Страница 42: ...D Master Alarm Signals The master alarm signals which are pre loaded in the database see page 19 will appear in the sequence below starting at the top of the first column to the bottom of the first c...

Страница 43: ...es LCD Alarm Systems Powerex 150 Production Drive Harrison OH 45030 USA P 1 888 769 7979 F 513 367 3125 www powerexinc com IN597400AV 08 2016 Page 43 of 56 Appendix E Digital Alarm or Master Alarm Wir...

Страница 44: ...D Alarm Systems Powerex 150 Production Drive Harrison OH 45030 USA P 1 888 769 7979 F 513 367 3125 www powerexinc com IN597400AV 08 2016 Page 44 of 56 Appendix F Remote Mounting of Digital Touch Scree...

Страница 45: ...Systems Powerex 150 Production Drive Harrison OH 45030 USA P 1 888 769 7979 F 513 367 3125 www powerexinc com IN597400AV 08 2016 Page 45 of 56 Appendix G Wiring Schematic Equipment Wiring to Digital...

Страница 46: ...larm Systems Powerex 150 Production Drive Harrison OH 45030 USA P 1 888 769 7979 F 513 367 3125 www powerexinc com IN597400AV 08 2016 Page 46 of 56 Appendix H Remote Mounting of Digital Touch Screen M...

Страница 47: ...Alarm Systems Powerex 150 Production Drive Harrison OH 45030 USA P 1 888 769 7979 F 513 367 3125 www powerexinc com IN597400AV 08 2016 Page 47 of 56 Appendix I Equipment wiring to Digital Touch Screen...

Страница 48: ...rm Systems Powerex 150 Production Drive Harrison OH 45030 USA P 1 888 769 7979 F 513 367 3125 www powerexinc com IN597400AV 08 2016 Page 48 of 56 Appendix J Digital Touch Screen Alarm Ethernet Ribbon...

Страница 49: ...s LCD Alarm Systems Powerex 150 Production Drive Harrison OH 45030 USA P 1 888 769 7979 F 513 367 3125 www powerexinc com IN597400AV 08 2016 Page 49 of 56 Appendix K Electrical Wiring Schematic with B...

Страница 50: ...LCD Alarm Systems Powerex 150 Production Drive Harrison OH 45030 USA P 1 888 769 7979 F 513 367 3125 www powerexinc com IN597400AV 08 2016 Page 50 of 56 Appendix L Ethernet Ribbon Cable and BACnet Co...

Страница 51: ...D Alarm Systems Powerex 150 Production Drive Harrison OH 45030 USA P 1 888 769 7979 F 513 367 3125 www powerexinc com IN597400AV 08 2016 Page 51 of 56 Appendix M Text Message Carriers char Carriers SM...

Страница 52: ...Med Touch Series LCD Alarm Systems Powerex 150 Production Drive Harrison OH 45030 USA P 1 888 769 7979 F 513 367 3125 www powerexinc com IN597400AV 08 2016 Page 52 of 56...

Страница 53: ...Med Touch Series LCD Alarm Systems Powerex 150 Production Drive Harrison OH 45030 USA P 1 888 769 7979 F 513 367 3125 www powerexinc com IN597400AV 08 2016 Page 53 of 56...

Страница 54: ...Program IP PGW Program Gateway IP PMI Program SMTP Mail Server IP PUN Program User Name PUP Program User Password PCX Program Contacts for Alarm Panel 1 2 3 4 5 Common Commands PPN Program Panel Name...

Страница 55: ...taxes duties licenses or other fees imposed by any governmental authority upon the production sale shipment and or use of Products covered hereunder The warranties and remedies herein are the sole and...

Страница 56: ...d or use of Products for certain purposes which may vary from those in neighboring areas While Powerex attempts to assure that its Products comply with such codes it cannot guarantee compliance and ca...

Отзывы: