TO PROTECT AGAINST RUST FORMATION DURING STORAGE, OIL
THE CYLINDER BORE:
• Remove spark plug and pour approximately 15 ml of clean engine oil into the
cylinder.
• Install spark plug.
• Make sure engine
ON/OFF
switch is
OFF
. Slowly pull the starter cord 2 to 3 times to
distribute and coat the cylinder bore with oil.
DO NOT
start engine at this time.
Unintentional sparking can cause fire or electrical shock.
Failure to observe this warning can cause severe property
damage, severe burns and even death.
Disconnect spark plug wire from spark plug and cover tip of spark plug wire
with insulating tape and place wire where it cannot come in contact with
spark plug or Waterblaster frame.
PRESSURE PUMP
1. Drain all water from pressure hose, coil and store it in cradle of pressure
washer handle.
2. Drain all water from spray gun and spray wand by holding spray gun in vertical
position with nozzle pointed downward. Squeeze trigger to remove fluids from
spray gun and spray wand. Store in spray gun/hose holder.
3. Store chemical hose, high pressure hose and spray wand so they are protected
from damage, such as being run over.
It is
RECOMMENDED
that you follow these steps to protect the internal seals of
Waterblaster when storing unit for more than 30 days and/or when freezing temper-
atures are expected.
1. Obtain a funnel, six ounces of RV antifreeze and approximately 0.9 m of garden
hose with a male hose connector on one end.
Use only RV antifreeze.
Any other type of antifreeze is
corrosive and can damage pressure pump.
2. Connect 0.9 meters length of garden hose to water inlet of pressure pump.
3. Add RV antifreeze using the funnel.