background image

Page 4  — English

iMPORTANT SAFETy iNSTRUCTiONS

SPECiFiC SAFETy RULES

 

Use only authorized replacement parts and accessories 
and follow instructions in the 

Maintenance

 section of this 

manual. Use of unauthorized parts or failure to follow 
maintenance instructions may create a risk of shock or 
injury.

 

Maintain the unit per maintenance instructions in this 
Operator’s Manual.

 

Inspect the unit before each use for loose fasteners, fuel 
leaks, etc. Replace damaged parts.

WARNiNG:

When this generator is used to supply a building 
wiring system:

 generator must be installed by a quali-

fied electrician and connected to a transfer switch as 
a separately derived system in accordance with NFPA 
70, National Electrical Code. The generator shall be 
connected through a transfer switch that switches all 
conductors other than the equipment grounding con-
ductor. The frame of the generator shall be connected to 
an approved grounding electrode. Failure to isolate the 
generator from power utility can result in death or injury 
to electric utility workers. 

 

Do not use this generator to provide power for emergency 
medical equipment or life support devices.

 

This generator has a neutral bonded condition. This 
means the neutral conductor is electrically connected to 
the frame of the machine.

 

Exhaust contains poisonous carbon monoxide, a colorless, 
odorless gas. Breathing exhaust can cause loss of con-
sciousness and can lead to death. If running in a confined 
or partially-enclosed area, the air may contain a danger-
ous amount of carbon monoxide. To keep exhaust fumes 
from building up, always provide adequate ventilation.

 

Always use a battery-powered carbon monoxide detec-
tor when running the generator. If you begin to feel sick, 
dizzy, or weak while using the generator, shut it off and 
get to fresh air immediately. See a doctor. You may have 
carbon monoxide poisoning.

 

Place the generator on a flat, stable surface with a slope 
of no more than 4°.

 

Operate in a well-ventilated, well-lit area isolated from 
working areas to avoid noise interference.

 

Operating the generator in wet conditions could result in 
electrocution. Keep the unit dry.

 

Keep the generator a minimum of 3 feet away from all 
types of combustible material. 

 

Do not operate generator near hazardous material.

 

Do not operate generator at a gas or natural gas filling 
station.

 

Do not touch the muffler or cylinder during or immediately 
after use; they are HOT and will cause burn injury.

 

Do not allow the generator’s gas tank to overflow when 
filling. Fill to 1 in. below the top neck of the gasoline tank 
to allow for fuel expansion. Do not cover the fuel tank cap 
when the engine is running. Covering the fuel tank cap 
during use may cause engine failure and/or damage to 
the tool.

 

Do not smoke when filling the generator with gasoline.

 

Shut down the engine and allow to cool completely before 
adding gasoline or lubricant to the generator.

 

Do not remove the oil dipstick or the fuel tank cap when 
the engine is running.

 

Pay close attention to all safety labels located on the 
generator.

 

Keep children a minimum of 10 feet away from the gen-
erator at all times.

 

The unit operates best in temperatures between 23°F and 
104°F with a relative humidity of 90% or less.

 

Operating voltage and frequency requirement of all 
electronic equipment should be checked prior to plug-
ging them into this generator. Damage may result if the 
equipment is not designed to operate within a +/- 10% 
voltage variation, and +/- 3 hz frequency variation from 
the generator name plate ratings. To avoid damage, al-
ways have an additional load plugged into the generator 
if solid state equipment (such as a television set) is used. 
A power line conditioner is recommended for some solid 
state applications.

 

For outdoor use only.

 

Save these instructions. Refer to them frequently and use 
them to instruct others who may use this product. If you loan 
someone this product, loan them these instructions also.

Содержание PS903500A

Страница 1: ...ng this product If you do not understand the warnings and instructions in the operator s manual do not use this product NOTICE AVISO Do not use E15 or E85 fuel or fuel containing greater than 10 ethan...

Страница 2: ...ncador retr ctil J Air filter filtro de aire K Choke anegador L Fuel tank vapor vent v lvula antirretorno M Ground terminal terminal de conexi n a tierra N Fuel valve interruptor del motor O AC circui...

Страница 3: ...e de mango D B A E A B 1 Axle eje 2 Wheel rueda 3 Washer arandela 4 Hitch pin pasador del enganche 5 Bolt tornillo 6 Rubber foot pie de goma 7 Lock nut tuerca de bloqueo 8 Engine lubricant lubricante...

Страница 4: ...ip mango del arrancador retr ctil A Knob perilla B Air filter cover tapa del filtro de aire C Filter element elemento de filtro D Air filter unit unidad del filtro de aire a b c d A Oil cap dipstick t...

Страница 5: ...aceite Fig 17 A Carburetor drain screw tornillo de drenaje del carburador Fig 21 B A A Fuel line conducto de combustible B Fuel filter filtro de combustible a b b a A Spark arrestor parachispas B Scr...

Страница 6: ...National Electric Code contains several practical ways in which to establish a good ground source If a steel or iron rod is used it should be at least 5 8 in diameter and if a nonferrous rod is used...

Страница 7: ...t Do not start or operate the engine in a confined space building nearopenwindows orinotherunventilatedspace where dangerous carbon monoxide fumes can collect Carbon monoxide a colorless odorless and...

Страница 8: ...isoning Place the generator on a flat stable surface with a slope of no more than 4 Operate in a well ventilated well lit area isolated from working areas to avoid noise interference Operating the gen...

Страница 9: ...use severe burns or death Hot Surface To reduce the risk of injury or damage avoid contact with any hot surface Lifting Hazard To reduce the risk of serious injury avoid attempting to lift the generat...

Страница 10: ...ator If any of the labels come off the unit or become hard to read contact an authorized service center for replacement DANGER PELIGRO Usar un generador en el interior PUEDE MATARLO EN POCOS MINUTOS L...

Страница 11: ...to be grounded to an approved earth ground Hot SURFACE warning Do not touch the muffler or aluminum cylinder of the engine They are very HOT and will cause severe burns Don t put any flammable or com...

Страница 12: ...to estimate the watts required to start electric motors however if an electric motor fails to start or reach running speed turn off the appliance or tool immediately to avoid equipment damage Always...

Страница 13: ...may damage the generator and or electrical devices connected to it electrical POWER MANAGEMENT To prolong the life of the generator and attached devices it is important to take care when adding electr...

Страница 14: ...rotect against electrical shock Consult with a local electrician for grounding requirements in your area Low Oil Shut Down Protector The low oil sensor causes the engine to stop if the level of oil in...

Страница 15: ...product with damaged or missing parts could result in serious personal injury WARNING Do not attempt to modify this product or create acces sories not recommended for use with this product Any such al...

Страница 16: ...t to make you careless Remember that a careless fraction of a second is sufficient to inflict serious injury WARNING Do not use any attachments or accessories not recom mended by the manufacturer of t...

Страница 17: ...d Unscrew the oil cap dipstick and remove Wipe dipstick clean and re seat in hole do not re thread Remove dipstick again and check lubricant level Lubri cant level should fall between the hatched area...

Страница 18: ...il the engine stops To stop the unit quickly in an emergency Press and hold the STOP switch until the engine stops warning While operating and storing keep at least 3 feet of clear ance on all sides o...

Страница 19: ...more completely WARNING Do not change engine lubricant while it is hot Accidental contact with hot engine lubricant could result in serious burns Reinstall the oil drain plug and tighten securely Refi...

Страница 20: ...for ward until knob snaps securely into position draining the carburetor Turn the engine switch off O Turn the fuel valve to the OFF position Position a suitable container under the carburetor drain...

Страница 21: ...n generator is used in dusty areas When generator has exceeded the maximum figures specified in the table maintenance should still be cycled according to the intervals of time or hours stated herein s...

Страница 22: ...gasoline or refueled with bad gasoline Checkairfilterelement Cleanor replace as needed Drain fuel and carburetor Refuel with fresh gasoline AC receptacle does not work Circuit breaker is off Item plug...

Страница 23: ...not cover Tune ups Spark Plugs Carburetor Carburetor Adjustments Ignition Filters Oil Change Wear items Recoil Starter Rope Engine Brushes Cotter Pins Wheels Warranty is voided if the customer fails t...

Страница 24: ...rosion and rust of engine parts 3 Repair required due to overheating Most often caused by overloaded or clogged or damaged or missing flywheel fan inlet air passages cooling fins or air shrouds 4 Dirt...

Страница 25: ...ed part that is scheduled only for regular inspection in the written instructions required by subsection d must be warranted for the warranty period defined in Subsection b 2 A statement in such writt...

Страница 26: ...in subsection b 2 If any such part fails during the period of warranty cov erage it must be repaired or replaced by the manufacturer issuing the warranty Any such part repaired or replaced under the w...

Страница 27: ...este generador deben conectarse apropiadamente a tierra mediante el uso de un tercer alambre o tener un dise o con doble aislamiento Se recomienda 1 Usar dispositivos el ctricos con clavija de tres p...

Страница 28: ...tilicenestaunidadni osnipersonascarentes de la debida instrucci n para su manejo Nohagaarrancarofuncionarelmotorenunespacioconfinado de edificio cerca de ventana abiertas o en otro rea sin ventilaci n...

Страница 29: ...o y respire aire fresco de inmediato Vea a un doctor Puede sufrir intoxicaci n por mon xido de carbono Coloque el generador en una superficie estable horizontal con una pendiente no mayor de 4 Utilice...

Страница 30: ...reducir el riesgo de lesiones el usuario debe leer y comprender el manual del operador antes de usar este producto Alerta de condiciones h medas No exponga la unidad a la lluvia ni la use en lugares h...

Страница 31: ...os s mbolos le permitir utilizar mejor y de manera m s segura el producto S MBOLO nombre designaci n explicaci n A Amperios Corriente Hz Hertz Frecuencia ciclos por segundo W Watt Potencia hrs Horas T...

Страница 32: ...a una tierra aprobada Advertencia de SUPERFICIE caliente No toque el silenciador ni el cilindro de aluminio del motor Est n muy CALIENTES y causan quemaduras graves No ponga ning n material inflamabl...

Страница 33: ...otencia necesaria en vatios para arrancar los motores el ctricos de C digo G no obstante si un motor el ctrico no arranca o no alcanza la velocidad de funcionamiento apague el dispositivo o herramient...

Страница 34: ...anual 2 Enchufe y active la primera carga preferiblemente la m xima carga que tenga 3 Deje que se estabilice la salida del generador el motor marcha uniformementeyeldispositivoacopladofuncionacorrecta...

Страница 35: ...isitos de conexi n a tierra en el rea geogr fica donde se encuentre usted Protecci n de apagado por baja cantidad de aceite El sensor de bajo nivel de aceite provoca la detenci n del motor cuando el n...

Страница 36: ...eza Usar este producto con partes da adas o faltantes puede causar lesiones serias al operador ADVERTENCIA No intente modificar esta producto ni introducir accesorios no recomendados para la misma Cua...

Страница 37: ...un instante es suficiente para causar una lesi n grave ADVERTENCIA No utilice ning n aditamento o accesorio no recomendado por el fabricante de este producto El empleo de aditamentos o accesorios no...

Страница 38: ...a asentarla en el agujero no la enrosque Retire de nuevo la varilla medidora de lubricante y verifique el nivel de lubricante El nivel de lubricante siempre debe estar entre las reas cubierta con ray...

Страница 39: ...1 Para apagar el motor en condiciones normales de funcionamiento Desconecte del generador toda carga presente Ponga la v lvula de combustible en la posici n OFF APAGADO Presione y sostenga el interrup...

Страница 40: ...letamente el lubricante NOTA Drene el lubricante mientras est tibio el motor no caliente El lubricante tibio se drena con mayor facilidad y compleci n ADVERTENCIA No cambie el lubricante del motor cua...

Страница 41: ...cierre la v lvula y vuelva a instalar el conducto en la llave de purga Vuelva a colocar la perilla de la v lvula del combustible en el alojamiento del generador Empuje hacia adelante hasta que la per...

Страница 42: ...e mantenimiento debe ser mayor si se el generador se usa en zonas de mucho polvo Si el generador ha sobrepasado los valores m ximos especificados en el cuadro aun debe seguirse el programa de mantenim...

Страница 43: ...tamiento ni vaciado de gasolina o reabastecido de gasolina de mala calidad Compruebe el elemento de filtro de aire Limpie o reemplace seg n sea necesario Vac e el combustible y el carburador Reabastez...

Страница 44: ...ta garant a no cubre Afinaci n Buj as carburador ajustes del carburador encendido filtros cambio de aceite Desgaste de piezas Cuerda del arrancador retr ctil escobillas del motor pasadores de chaveta...

Страница 45: ...cargas o por volantes ventiladores pasajes de entrada de aire aletas de enfriamiento o cubiertas de enfriamiento obstruidos da ados o faltantes 4 El desgaste relacionado con la suciedad o mugre causad...

Страница 46: ...ant a durante el per odo de garant a restante 2 Cualquier pieza cubierta por la garant a que tiene solamente una inspecci n regular programada en las instrucciones escritas requerida por la subsecci n...

Страница 47: ...to debe ser garantizada por el tiempo de garant a definido en la subsecci n b 2 Si cualquier de dichas partes fallan durante el tiempo de la cobertura de la garant a debe ser reparada o reemplazada po...

Страница 48: ...e personalmente Para obtener informaci n sobre el establecimiento de servicio autorizado m s cercano a usted le suplicamos llamar al 1 877 617 3501 PIEZAS DE REPUESTO El n mero de modelo de este produ...

Отзывы: