Guidance and manufacture’s declaration – electromagnetic immunity –

for all ME EQUIPMENT and ME SYSTEMS

Guidance and manufacture’s declaration – electromagnetic immunity

The Pro5M is intended for use in the electromagnetic environment specified below. The customer or the user of 
Pro5M should assure that it is used in such an environment.

Immunity test 

IEC 60601 test level 

Compliance level 

Electromagnetic environment - guidance

Electrostatic  

±6 kV contact 

±6 kV contact 

Floors should be wood, concrete or  

discharge (ESD) 

±8 kV air  

±8 kV air 

ceramic tile. If floor are covered with  

IEC 61000-4-2 

 

 

synthetic material, the relative humidity  

   

 

 

should be at least 30%.

Electrical fast  

±2 kV for power 

±2kV for power 

Mains power quality should be that of  

transient/burst 

supply lines 

supply lines 

a typical commercial or hospital   IEC 

61000-4-4  

 

environment.

Surge 

± 1 kV line(s) t 

±1 kV differential 

Mains power quality should be that of  

IEC 61000-4-5 

o line(s) 

mode 

a typical commercial or hospital    

  

 

 

environment.

Voltage dips, short 

<5% U

T

  

<5% U

T

  

Mains power quality should be that  

interruptions and 

(>95% dip in U

T

(>95% dip in U

T

of a typical commercial or hospital  

voltage variations 

for 0.5 cycle 

for 0.5 cycle 

environment. If the user of the Pro5M  

on power supply 

 

 

requires continued operation during  

input lines 

40% U

T

 

40% U

T

 

power mains interruptions, it is   IEC 

61000-4-11 

(60% dip in U

T

(60% dip in U

T

recommended that the Pro5M be powered  

   

for 5 cycles 

for 5 cycles 

from an uninterruptible power supply or a  

  

 

 

battery. 

    

70% U

T

 

70% U

T

 

   

(30% dip in U

T

(30% dip in U

T

)

   

for 25 cycles 

for 25 cycles 

   

<5% U

T

  

<5% U

T

  

 

   

(>95% dip in U

T

(>95% dip in U

T

   

for 5 sec 

for 5 sec

Power frequency  

3A/m 

3A/m 

Power frequency magnetic fields should  

(50Hz) magnetic 

 

 

be at levels characteristic of a typical  

61000-4-8 

 

 

location in a typical commercial or  

   

 

 

hospital environment.

 

NOTE   U

T

 is the a.c. mains voltage prior to application of the test level.

13

Содержание Pro5M

Страница 1: ...English Instructions for Use Pro5M Model Medical Device...

Страница 2: ...o5HP My7M my7 my5 my3 Personal MOVE Pro4PlusM and proMOTION are registered trademarks and or trademarks of Peformance Health Systems and or their affiliates All other trademarks are the property of th...

Страница 3: ...int dizzy nauseous short of breath or in pain stop exercising immedia tely and consult with your physician Body posture muscle stiffness and muscle tension are important contributing factors in your t...

Страница 4: ...ectively make up the circulatory system Pulmonary circulation is the portion of the cardiovascular system which transports oxygen depleted blood away from the heart to the lungs and returns oxygenated...

Страница 5: ...variation and the shape of the bones and cartilage that make up the joint Pathology Studies Claim Power Plate training can be a beneficial tool intervention to improve general well being fitness and d...

Страница 6: ...ing on and off the machine Never reach into or under the machine or tip the machine on its side while it is in operation Use the machine only for the purposes described in this user manual and only wi...

Страница 7: ...ssible injury from the machine s vibrations Power Plate recommends that the user not lean back on his her heels or lock his her joints or straighten his her legs when standing upright on the machine I...

Страница 8: ...are used in such an environment Floors should be wood concrete or ceramic tile If the floor is covered with synthetic material the relative humidity in the room should be at least 30 Mains power qual...

Страница 9: ...machine so that it is difficult to disconnect the main plug Warning To avoid the risk of electric shock this equipment must only be connected to a supply main with protective earth grounding This appl...

Страница 10: ...Operation Power Plate pro5 face plate 10...

Страница 11: ...in your training The Power Plate machine is very easy to operate as you can tell from a brief review of the primary buttons on the face plate 1st Main Controls Start Repeat 2nd Frequency 25 50Hz 1Hz i...

Страница 12: ...unction Therefore its RF emissions are very low and are not likely to cause any interfe rence in nearby electronic equipment RF emission CISPR 11 Class B Class A with IEC61000 3 2 Complies with IEC610...

Страница 13: ...nment Surge 1 kV line s t 1 kV differential Mains power quality should be that of IEC 61000 4 5 o line s mode a typical commercial or hospital environment Voltage dips short 5 UT 5 UT Mains power qual...

Страница 14: ...eld strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of...

Страница 15: ...42 EEC Date of manufacture Manufacturer Type B applied part DISPOSAL Do not dispose this product as unsorted municipal waste Collection of such waste separately for special treatment is necessary CB C...

Страница 16: ...ises can be added When trying to accomplish weight loss cardiovascular or endurance improvements rest time can be reduced exercise time can be extended and the number of exercises can be increased to...

Страница 17: ...cademies For more information please visit our website www powerplate com PersonalAdaptation Training on the Power Plate machine is like any other type of training start with light and short training...

Страница 18: ...rtz 30 45 or 60 seconds Up to 9 minutes TimeSelections VibrationEnergyOutput Low or High DimensionsWxDxH 96 x 114 x 153 cm 38 x 45 x 60 SurfacePlateDimensionsWxD 96 x 114 cm 38 x 45 Weight 185 kilogra...

Страница 19: ...tions are proper please check the circuit breaker or fuse for the electrical outlet that is supplying power to the machine in order to ensure that the outlet is receiving electrical power If the conso...

Страница 20: ...y be obtained by contacting Power Plate through the Contact Us page online or by writing to Power Plate Performance Health Systems UK Ltd Business Design Centre Unit 115 52 Upper Street Islington Lond...

Отзывы: