background image

Power-Flo Pumps & Systems • 877-24PUMPS • www.powerfl opumps.com

4

Specifi cations

MODEL

HP

Hz

Volts/Ph

RPM

Full Load 

Amps

Locked 

Rotor Amps

NEMA Start 

Code

Cord 
Type

Cord 

Size

Cord 

O.D.

PFG3022*

›

3

60

230/1

3450

26

90

H

SOW

10/4

.75

PFG3062

3

60

208/3

3450

17

65

J

SOW

10/4

.75

PFG3032

3

60

230/3

3450

14.5

62

K

SOW

10/4

.75

PFG3042

3

60

460/3

3450

7.2

31

K

SOW

10/4

.75

PFG5022*

5

60

230/1

3450

39

136

H

SOW

10/4

.75

PFG5062

5

60

208/3

3450

25

122

K

SOW

10/4

.75

PFG5032

5

60

240/3

3450

21.9

120

L

SOW

10/4

.75

PFG5042

5

60

460/3

3450

11

60

L

SOW

10/4

.75

PFG7532

7.5

60

230/3

3450

22.3

136

J

SOW

10/4

.75

PFG7542

7.5

60

460/3

3450

11.2

68

J

SOW

10/4

.75

Moisture & Temperature sensor cable for all other models is 18/5 SOW. 0.47 inches O.D. See page 17 for Relay kits.

(*)

 IMPORTANT!

 - These pumps require a control panel with start, run capacitors and relay. Capacitor kits which include Start & 

Run capacitors and Start Relay, are available if a Power-Flo control panel is not used, see page 17.

PFG 3, 5 & 7.5HP   

 

  

      

       

 

 Submersible Grinder Pumps

Recommended Breaker & Heater Sizes

MODEL

HP

Hz

Volts/Ph

Breaker Size

Heater 

Size **

Voltage Relay

Start Capacitor

Run Capacitor

PFG3022*

›

3

60

230/1

80 AMP

K-70

MARS 64

189-227 mfd-220 volt

40 mfd - 370 volt

PFG3062

3

60

208/3

40 AMP

K-56

N/R

N/R

N/R

PFG3032

3

60

230/3

30 AMP

K-54

N/R

N/R

N/R

PFG3042

3

60

460/3

15 AMP

K-41

N/R

N/R

N/R

PFG5022*

5

60

230/1

80 AMP

K-70

MARS 64

189-227 mfd-220 volt

40 mfd - 370 volt

PFG5062

5

60

208/3

50 AMP

K-63

N/R

N/R

N/R

PFG5032

5

60

240/3

50 AMP

K-62

N/R

N/R

N/R

PFG5042

5

60

480/3

20 AMP

K-50

N/R

N/R

N/R

PFG7532

7.5

60

230/3

50 AMP

K-67

N/R

N/R

N/R

PFG7542

7.5

60

460/3

30 AMP

K-54

N/R

N/R

N/R

N/R = Not Required
Winding resistance ± 5% at terminal block.   Rated operation at ± 10% voltage at motor.
(**) Recommended heater sizes may very depending on pump station requirements.
(

›

 ) This data is for the PFG3022, from Sept 2010 and newer. For units prior to Sept 2010 use to following: FLA - 21.7, LRA - 75, 

NEMA code - G, Breaker Size -  50amp, Heaters K-64, Relay MARS 65, Start Cap. 257mfd - 220volts, Run Cap. 20mfd-370volts.

Содержание PFG3022

Страница 1: ...om ISP No PFGrinder357 5 13 INSTALLATION SERVICE PARTS MANUAL Power Flo Pumps Systems 877 24PUMPS www powerflopumps com Series PFG3022 PFG3062 PFG3032 PFG3042 PFG5022 PFG5062 PFG5032 PFG5042 PFG7532 P...

Страница 2: ...only Keep clear of suction and discharge openings Do not insert fingers in pump with power connected Always wear eye protection when working on pumps Do not wear loose clothing that may become entangl...

Страница 3: ...il Lubricated LOWER BEARING Sleeve Oil Lubricated POWER CORD 30 ft Cord Pressure grommet for Sealing and Strain Relief MOTOR Oil Filled Squirrel Cage Induction Class F Insulation SINGLE PHASE Capacito...

Страница 4: ...if a Power Flo control panel is not used see page 17 PFG 3 5 7 5HP Submersible Grinder Pumps Recommended Breaker Heater Sizes MODEL HP Hz Volts Ph Breaker Size Heater Size Voltage Relay Start Capacito...

Страница 5: ...Power Flo Pumps Systems 877 24PUMPS www powerflopumps com 5 Performance PFG 3 5 7 5HP Submersible Grinder Pumps...

Страница 6: ...Controls PFG series grinders require a separate approved pump control device or panel for automatic operation Be sure the electrical specification of the control selected properly match the electrical...

Страница 7: ...minimum level of 10 inches above the basin floor Electrical Connections Power cable The power cable mounted to the pump must not be modified in any way except for shortening to a specific application...

Страница 8: ...unit upright Remove pipe plug 30 from housing 8 With a flashlight visually inspect the oil in housing 8 to make sure it is clean and clear light amber in color and free from suspended particles Milky...

Страница 9: ...ove CAUTION Cutter edges are very SHARP Cutter must be removedbeforeremovingvolute Volute Remove hex nuts 25 and washers 9 from studs 26 and remove volute 23 and square ring 24 from pump Shredding Rin...

Страница 10: ...seal cavity in intermediate coupling 5 Lightly oil Do not use grease outer surface of stationary member Press seal s 4 stationary member firmly into intermediate coupling 5 using a seal tool or pipe...

Страница 11: ...Green Black 1 7 Red 2 8 White 3 9 T4 T5 T6 Together FIGURE 4 THREE PHASE 460 VOLT AC Power Cable Motor Lead Number Green Ground Green Black 1 Red 2 White 3 T4 T7 Together T5 T8 Together T6 T9 Together...

Страница 12: ...T Do not hammer on the seal pusher It will damage the seal face With seal guide tool over motor shaft Lightly oil Do not use grease guide shaft and inner surface of bellows on rotating seal With lappe...

Страница 13: ...Power Flo Pumps Systems 877 24PUMPS www powerflopumps com 13 Typical Panel Wiring Schematic PFG 3 5 7 5HP Submersible Grinder Pumps Figure 6...

Страница 14: ...UMPS www powerflopumps com 14 Figure 7 Repair Parts For Repair Part Please supply Model Number and MFG Date as shown on Name Plate and Part Description and Part Number as shown on Parts List PFG 3 5 7...

Страница 15: ...UMPS www powerflopumps com 15 Figure 8 Repair Parts For Repair Part Please supply Model Number and MFG Date as shown on Name Plate and Part Description and Part Number as shown on Parts List PFG 3 5 7...

Страница 16: ...10 4 SOW PF31030003 13B 1 Hex Plug PF30400903 13C 2 Friction ring PF91010055 13D 1 Grommet PF92010001 14 1 Moisture Temperture Sensor Cable 18 5 SOW 30Ft PF31030005 14B 1 Hex plug PF30400901 14C 2 Fr...

Страница 17: ...l Bearing 6203ZZ PF070715 Repair Kits CUTTER KIT Includes Item numbers 20 27 28 29 PFGL CT 6 OVERHAUL KIT Includes Item numbers 2 3 4 6 7 20 24 27 28 29 34 PFGL OHK SEAL PROBE KIT Includes item number...

Страница 18: ...Power Flo Pumps Systems 877 24PUMPS www powerflopumps com 18 Notes PFG 3 5 7 5HP Submersible Grinder Pumps...

Страница 19: ...hole 10 Check rotation If power supply is three phase reverse any two of three power supply leads to ensure proper impeller rotation 11 Repair fixtures as required to eliminate leakage 12 Check pump t...

Страница 20: ...that has not been installed operated or maintained in accordance with Manufacturer s installation instructions that has been exposed to outside substances including but not limited to the following sa...

Отзывы: