1/2 in. Air Ratchet and Socket Set
6
For technical questions call 1-800-665-8685
8395881
V 2.5
AIR COMPRESSOR
Ensure the compressor used with the tool can supply the required Cubic Feet per Minute at the required PSI
(see Specifications).
1. Use proper size and type of air pressure line and fittings.
2. Use only clean, dry, regulated compressed air at the rated range as marked on the tool.
CAUTION! Do not use an air source other than an air compressor to power this tool.
3. Always use an air regulator, an in-line filter and a
moisture trap in your compressed air system. These
accessories will increase the tool’s life and keeps the
tool in good working condition.
See the diagram for
recommended components of an air line.
4. Avoid using an air hose that is too long. The longer
the hose, the lower the pressure that reaches the tool,
possibly causing it to cease functioning. As well, a
longer hose can become a tripping hazard.
5. Air tool CFM consumption ratings are based upon a
25% duty cycle. If you require continuous duty, a larger
compressor is required.
AIR SOURCE INSTALLATION
WARNING! Never use pure oxygen, carbon dioxide,
combustible gases or any bottled gas as an air source for a
tool. Such gases are capable of causing an explosion and
serious injury to persons.
1. Set the air pressure regulator on the air compressor to the recommended PSI level (see Specifications). Do
not exceed the tool recommended air pressure. Excess pressure could result in damage to the tool, to your
workpiece or serious injury.
2. Prepare a standard 1/4 in. air connector (provided) for use with your tool. Wrap the threaded portion of the
air connector with thread tape. Wrap in a clockwise direction so it will not unravel when attaching to a quick
connector. Attach it to the tool air inlet and tighten.
3. Attach a standard quick connector to the air source’s hose. Attach the air hose to the tool’s air connector.
4. Check the air line and its connections for air leaks. Do not use the tool until you have repaired all air leaks.
DISCONNECTING AIR SOURCE
WARNING! Failure to follow these steps could result in severe injury, tool or property damage.
Disconnect tool from air source before cleaning, servicing, changing parts/accessories or when not in use.
1. Turn the air regulator to the OFF or L position.
2. Turn off the air compressor.
3. Disconnect the air pressure hose.
4. Discharge any residual pressure inside the tool.