SD300 SERIES
POWER ELECTRONICS
40
POWER CONNECTION
Dynamic Braking Resistors
A dynamic brake controls the regenerated energy. The dynamic brake activates an IGBT to discharge the
DC bus over external resistors when the DC voltage overpasses a pre-set value.
SD300 drives include a built-in dynamic brake as standard. The user only has to connect a resistor between
terminals P2 and B of the power board (see Section 7.3).
Reference
Input voltage
(V)
Drive
capacity
(kW)
100%
Braking
150%
Braking
Ω
W*
Ω
W*
SD300312, SD300312F, SD300322, SD300326
230
0.4
400
50
300
100
SD300612, SD300612F, SD300622, SD300526
0.75
200
100
150
150
SD300912, SD300912F, SD300922, SD300826
1.5
100
200
60
300
SD301212, SD301212F, SD301222, SD301126
2.2
60
300
50
400
SD301822, SD301726
4
40
500
33
600
SD303022, SD302426
5.5
30
700
20
800
SD304022, SD303226
7.5
20
1000
15
1200
SD305622, SD304626
11
15
1400
10
2400
SD306922, SD306026
15
11
2000
8
2400
SD300242, SD300242F, SD300146, SD300146F
400
0.4
1800
50
1200
100
SD300342, SD300342F, SD300246, SD300246F
0.75
900
100
600
150
SD300542, SD300542F, SD300446, SD300446F
1.5
450
200
300
300
SD300742, SD300742F, SD300646, SD300646F
2.2
300
300
200
400
SD301042, SD301042F, SD300946, SD300946F
4
200
500
130
600
SD301642F, SD301246, SD301246F
5.5
120
700
85
1000
SD302342F, SD301646, SD301646F
7.5
90
1000
60
1200
SD303042F, SD302446, SD302446F
11
60
1400
40
2000
SD303842F, SD303046, SD303046F
15
45
2000
30
2400
SD304442F, SD303946, SD303946F
18.5
35
2400
20
3600
SD305842F, SD304546, SD304546F
22
30
2800
10
3600
Notes:
The values of the braking resistors that appear in the table are the minimum recommended values.
For a customized calculation, and adjusted to your application, please contact Power Electronics.
The braking resistor should be non-inductive.
To connect the sensor to the drive, it is recommended to use shielded cable.
The maximum cable length between the drive and the external braking resistor is 20m. For other
configurations, contact with Power Electronics.
CAUTION
Do not touch the braking resistor during the drive operation. It could be very hot (over 150ºC).
Содержание SD300146
Страница 1: ...VARIABLE SPEED DRIVE Variable Speed Drive Hardware and Installation Manual...
Страница 2: ......
Страница 3: ...Variable Speed Drive Hardware and Installation Manual Edition February 2017 SD30MTHW01CI Rev C...
Страница 4: ...SD300 SERIES POWER ELECTRONICS 2 SAFETY SYMBOLS...
Страница 62: ...SD300 SERIES POWER ELECTRONICS 60...
Страница 65: ...www power electronics com...