Powered by Safety
®
39
Troubleshooting
01.4IB.48040C
Ch 6 Troubleshooting
A. t
rOuBleSHOOting
tHe
f
iBer
-O
ptic
p
rOBeS
1.
Problem
: Sensor / LOI mapping. The user is
unsure about which sensors are mapped to
which locations. This can happen if several
wire tags fall off during the installation of
the fibers.
a. Identify the unknown fibers at their
respective LOIs.
b. Apply an indirect heat source to the
vicinity of the LOI. Heat guns are
recommended for the task but should
never be directly applied to the fiber or
the sensing tip. Heat the adjacent area.
c. Return to the G3 Conversion Module
and identify which unknown sensor has
shown an increase in temperature due
to the application of heat.
d. Alternatively, apply a heat source
sequentially to each fixture and look for
a change in measured temperature.
e. Repeat the process above until all fibers
have been properly identified and
marked.
2.
Problem
: BriteSpot™ Indicator LEDs remain
red (optical signal too low)
a. Determine if the problem is related to
the Fiber-Optic Probe or the Optical
Connection Port by moving the probe
in question to another port that has
already been determined to work. If the
Probe functions in the test port, then
the original Optical Connection Port is
likely the problem.
b. Optical Port Related Problems. Attempt
to blow any contaminants off the
surface of the LED inside the port with
clean compressed air. DO NOT USE
UNFILTERED, NON-INSTRUMENTATION
TYPE COMPRESSED AIR. Re-insert fiber
into connector and allow 30 seconds
to stabilize. Proceed to next step if
BriteSpot Indicator LED remains red.
c. Probe Related Problems
i. Trim ~3 mm (¹⁄8”) from the end of the
fiber. Re-insert fiber into connector
and allow 30 seconds to stabilize.
Proceed to next step if BriteSpot
Indicator LED remains red.
ii. Replace the Probe.
B. t
rOuBleSHOOting
tHe
O
nBOArd
w
eB
-
pAge
1.
Problem
: Web page does not display (HTTP
error 404)
a. Restart the unit.
b. Ensure the device is powered and
working (the SYS LED flashing green
and the LINK and 10/100 LEDs are on).
c. Ensure the Ethernet cable from the
device is connected to the computer.
d. Ensure the correct IP address is entered
in the address bar
e. If problem persists, perform Hardware
Reset.
2.
Problem
: The website isn’t loading properly
a. Restart the unit.
3.
Problem
: Memory capacity is 100%
Explanation: Once the memory is full it will
start writing over the beginning.
a. Download the Log file using the
application G3 and save it.
b. Erase the log, this will set the memory
back to 0%, follow the instructions in
“data Log section”.
Содержание BriteSpot BSG3
Страница 1: ...Instruction Bulletin 01 4IB 48040C BriteSpot BSG3 Powered by Safety ...
Страница 4: ...Powered by Safety BriteSpot BSG3 01 4IB 48040C This page is intentionally left blank ...
Страница 10: ...Powered by Safety BriteSpot BSG3 01 4IB 48040C This page is intentionally left blank ...
Страница 37: ...Powered by Safety 27 Usage 01 4IB 48040C Figure 34 LCD Menu and Navigation ...