Powered by Safety
®
14
Installation
01.4IB.48040C
BriteSpot™ BSG3
B. S
ecure
p
rOBe
tO
lOi
The most common Probe Mounting Fixture
for use with the BriteSpot™ system is based on
industry standard ring-style cable termination
lugs. These lugs have proven to be reliable,
easy to install, and virtually maintenance
free. In addition, if installed at locations
with existing hardware, no modifications to
hardware lengths or specifications are needed.
The fiber probe has a special feature, called the
Probe-Lock which secures the Probe to the lug
without crimping, allowing lugs to be installed
first, then the attachment of the probe.
Figure 9
Fiber-Optic Probe with Probe Lock
Probe Lock Setscrew
1. Select the proper lug of the application
based on the existing hardware (if present)
or planned hardware. Any #6 AWG
Tyco/Amp Solistrand™ ring-style lug should
be compatible, however not all have been
tested. If purchased in kit form, 1/2 inch
lugs have been included. Other sizes are
also available as seen in
. When
selecting the lug for a given location,
ensure that the lug with the tightest fit
around the hardware is selected – this aids
in proper thermal conduction and will
result in more accurate readings.
Figure 10 Tyco/Amp Ring Style Lugs
a
b
c
a. 1/2" Hardware (Tyco/Amp PN 36808)
b. 3/8" Hard ware (Tyco/Amp PN 36807)
c. 1/4" Hardware (Tyco/Amp PN 33465)
2. To make probe installation easier,
consideration must first be given to
the rotational orientation of the lug
before it is mounted. When the probe is
eventually installed, the fiber will need
to have a relatively unobstructed path
to be inserted into the lug. For example,
in some situations protective boots are
placed over bolted connections, posing
an inconvenience when routing the fiber.
Align the fixture to allow the fiber to be
threaded through existing seams in the
dielectric boot. The lug must also be placed
such that the Probe-Lock is accessible to an
Allen Key for tightening.
3. Mount the lug so that it is directly
contacting the surface to be measured.
Washers should NOT be placed between
the lug and the surface to be measured;
instead they should be placed on the other
side of the lug, as shown in
shows the proper installation
when Belleville washers are used.
Absolutely no greases and / or pastes
should be used between the lug and
the surface it is contacting. Ensure the
orientation of the lug is such that the probe
and fibre run parallel to the bus.
Содержание BriteSpot BSG3
Страница 1: ...Instruction Bulletin 01 4IB 48040C BriteSpot BSG3 Powered by Safety ...
Страница 4: ...Powered by Safety BriteSpot BSG3 01 4IB 48040C This page is intentionally left blank ...
Страница 10: ...Powered by Safety BriteSpot BSG3 01 4IB 48040C This page is intentionally left blank ...
Страница 37: ...Powered by Safety 27 Usage 01 4IB 48040C Figure 34 LCD Menu and Navigation ...