24 Commissioning
Part No. 27/20334
Commissioning - Page 24
3.6
D.H.W Flow Rate
The appliance contains an automatic flow regulator
supplying a nominal flow rate of 12 litres/minute.
3.7
Central Heating
a)
Ensure that all external controls such as a timers are
switched On and that room thermostat/s are calling for
heat.
b)
Set the Central Heating switch to Timed (if system
fitted with Timer) or Constant. The appliance will
operate in accordance with the pre-selected
temperature set on the temperature control knob.
3.8
Temperature Controls
a)
Central Heating
The control knob enables you to control the
temperature of the central heating flow as it leaves the
appliance. This knob can be set between the - and +
setting. The graduations correspond approximately to
a temperature of 60°C to 85°C. Under a minimum load
condition the flow temperature can rise to 90°C at
maximum setting. The appliance is fitted with a Central
Heating switch which will allow you to switch Off the
central heating during the summer months (mid
position).
b)
Hot Water
The tank thermostat is factory set for best
performance. The mixing valve on the tank outlet is
adjustable and should be set to deliver water at
approximately 60°C.
Ensure that the tank thermostat lead is connected.
3.9
Appliance Protection Devices
Loss of gas supply, flame failure, or over-heating of the
central heating water will cause the appliance to shut
down or Lockout.
This will be indicated by the lockout light being
illuminated. To Reset the appliance press the RESET
button on the front panel and hold in that position for
10 seconds and release. The appliance should now
operate normally.
If this is not the case refer to the Fault Finding guide
either on the rear of the white front case or Page 41 of
these instructions.
If the central heating system looses pressure for any
reason the appliance will overheat and lockout. The
system and the appliance should be checked for leaks
(including discharge from the pressure relief pipe).
Correct any faults and re-pressurise the system with
reference to Section 1.6. Mains Water Feed Central
Heating.
The tank protects the boiler against frost as long as the
boiler switch is set to 'On'.
Note:
While the appliance is being used to provide hot
water at any draw off point, the central heating will not
operate. When hot water is no longer required the
appliance will, after a few minutes, revert to central
heating.
Содержание Puma Flowsure+
Страница 5: ...Part No 27 20334 Introduction 5 Introduction Page 5 ...
Страница 28: ...28 Routine Maintenance Part No 27 20334 Routine Maintenance Page 28 ...
Страница 30: ...30 Routine Maintenance Part No 27 20334 Routine Maintenance Page 30 ...
Страница 34: ...34 Component Replacement Part No 27 20334 Component Replacement Page 34 ...
Страница 42: ...42 Control Flow Sequence Part No 27 20334 8 Control Flow Sequence Page 42 ...
Страница 43: ...Part No 27 20334 Functional Flow 43 9 Functional Flow Page 43 ...
Страница 44: ...44 Pictorial Wiring Diagram Part No 27 20334 10 Pictorial Wiring Diagram Page 44 ...
Страница 45: ...Part No 27 20334 Electrical Diagram 45 11 Electrical Diagram Page 45 ...
Страница 47: ...Part No 27 20334 Short List of Spares 47 Short List of Spares Page 47 Back page ...