43
13.0 Changing Components
© Baxi Heating UK Ltd 2016
13.20
Gas Valve (Fig. 65)
IMPORTANT: After replacing the valve the CO
2
must be
calibrated as detailed in Section 14.0 Combustion &
Calibration. Only change the valve if a suitable calibrated
combustion analyser is available, operated by a
competent person - see section 12.1.
1. Turn the gas cock off and undo the nut under the boiler.
Retain the washer.
2. Remove the electrical plug from the valve.
3. Undo the nut on the gas feed pipe and ease the pipe aside.
It is recommended that the injector washer is changed as well.
4. Remove the screws securing the gas valve to the boiler
bottom panel.
5. Reassemble in reverse order, ensuring the injector washer is
in place, and perform the Calibration Function & Combustion
Check - see Sections 14.1 & 14.2.
NOTE: Check for gas tightness after replacing gas valve.
13.21
Expansion Vessel (Fig. 66)
1. Close the flow and return isolation taps and drain the
primary circuit.
2. Undo the nut on the pipe connection at the bottom of the
vessel, and slacken the nut on the hydraulic inlet assembly.
3. Remove the screws securing the support bracket, and
withdraw the bracket.
4. Whilst supporting the vessel undo and remove the locknut
securing the vessel spigot to the boiler top panel.
5. Manoeuvre the vessel out of the boiler.
6. Reassemble in reverse order.
Gas Valve
Fig. 65
Expansion Vessel
Lock Nut
Fig. 66
Support Bracket
Gas Feed Pipe
Control Box removed
for clarity
Plug
Gas Cock
Injector
Washer
Washer
NOTE: The Injector Washer MUST
be fitted as shown between the
Valve & Pipe.
DO NOT fit the
Injector Washer between the Gas
Cock & Valve