Figure 12 LIFTING AND ALIGNING BOILER
Lift boiler onto the mounting bracket and adjust the boiler
position to obtain a minimum of 5mm clearance from any
side wall or cupboard.
Secure boiler to the mounting bracket using 5mm screw
from accessory pack C.
Undo the screws securing the transportation feet. Discard
feet and screws.
Correct vertical alignment with rear wall as necessary using
the adjustment screws.
Remove the temporary cardboard packing pieces from