Publication No. 5102977
27
CON0030D
Casing
Pressure
Pipe (White)
Fig. 26
4.2
Electronic Control Board
•
Gain General Access - See 4.1
For better access of controls tray See 4.1
Note 5.
1. Disconnect all connectors and wires,
unscrew the two securing screws and
remove the board.
2. On re-assembly refer to the wiring diagram
when re-connecting wires and connectors.
4.3
Air Pressure Switch
•
Gain General Access - See 4.1
1. Remove the securing screws and allow the
control panel to pivot forwards - see 4.1
Note 5.
2. Note the wire connections and disconnect
the wires to the air pressure switch.
3. Remove the screws securing the air
pressure switch to the bracket.
4. Note the tube connections and remove the
tubes from the switch.
5. Re-assemble in reverse order.
4.4
Temperature Sensor
•
Gain General Access - See 4.1
1. Disconnect the wires from the sensor.
2. Depress the clips on the outside of the
sensor and pull it clear of the heat exchanger.
3. Re-assemble in reverse order, use fresh
conducting paste.
4.5
Overheat Thermostat
•
Gain General Access - See 4.1
1. Disconnect the wires from the thermostat.
2. Unscrew the thermostat from the pipe.
3. Re-assemble in reverse order.
Service & Replacement of Parts
Содержание Kingfisher Mf CFL40 - 100
Страница 13: ...Publication No 5102977 13 CON0093B Installation Requirements Fig 8 Fig 7 ...
Страница 14: ...Publication No 5102977 14 Installation Requirements Fig 9 Fig 10 ...
Страница 30: ...Publication No 5102977 30 5 Wiring Diagrams Functional Wiring Diagram Fig 29 Air Pressure Switch CON0089A ...
Страница 31: ...Publication No 5102977 31 Fig 30 Pictorial Wiring Diagram CON0082B T T B CFL Models Only ...
Страница 34: ...Publication No 5102977 34 Fault Finding ...
Страница 35: ...Publication No 5102977 35 Fault Finding ...