16 Installation
Fig. 14
Centre of
the Flue
Cut Out Hole
Front Edge
Rear Edge
Top View of the Work top
Minimum
from Wall
Maximum
from Wall
135
Max.
C/L.
C/L.
115
85 Minimum
200
200
100
100
200
200
CON0075A
2. Attach the flue to the flue spigot.
This product is fitted with a combustion
products discharge safety device (TTB) which
must not be taken out of operation at any
time. The component is fitted to ensure that
any blockage or partial blockage of the flue
does not result in combustion products
discharging into the room.
Fitting under a Worktop (CFL Models)
1. Remove the top blanking plate from the
boiler (if already assembled).
2. See Section 4.9 on page 28 of the Installation
& Service Instructions, remove the products
discharge safety device (TTB) and carefully
place on top of the appliance.
3. Remove the flue spigot from the appliance
by removing the 4 adjusting screws.
4. Mark the centre of the flue on the work top
and cut a 200 mm square hole from this
centre point. The centre point should be a
minimum of 85 mm from the wall and a
maximum of 135 mm from the wall being
dependent on the boiler position.
5. Place boiler in position under the work top.
6. Re-fit the flue spigot as shown in Fig. 13.
7. Refit the products discharge safety device
(TTB) back onto the flue spigot and secure
with the screw.
8. It is a requirement that after disturbing the
products discharge safety device, a full
operational check should be made to ensure
correct operation i.e. with the boiler fully
operating, temporarily block the flue. The
safety discharge device should operate and
the boiler go to lockout in less than 2
minutes.
9. Unblock the flue after the test.
Wall
Ceiling
(Combustible
Material)
Flue
Spigot
80
Min.
Plus 50
max
Minimum
25mm
clearance
Conventional
Flue
Top Blanking
Plate
Rear
Blanking
Plate
Flue
Spigot
Air Box
C
O
N0
03
4E
Fig. 13
Содержание Kingfisher Mf CFL40 - 100
Страница 13: ...Publication No 5102977 13 CON0093B Installation Requirements Fig 8 Fig 7 ...
Страница 14: ...Publication No 5102977 14 Installation Requirements Fig 9 Fig 10 ...
Страница 30: ...Publication No 5102977 30 5 Wiring Diagrams Functional Wiring Diagram Fig 29 Air Pressure Switch CON0089A ...
Страница 31: ...Publication No 5102977 31 Fig 30 Pictorial Wiring Diagram CON0082B T T B CFL Models Only ...
Страница 34: ...Publication No 5102977 34 Fault Finding ...
Страница 35: ...Publication No 5102977 35 Fault Finding ...