ODP 200 Technical Manual
73
68
EAN8
7
≤
n
≤
8
48
≤
d
≤
57
69
CODE39
1
≤
n
≤
255
48
≤
d
≤
57, 65
≤
d
≤
90,
32,36,37,43,45,46,47
70
ITF
1
≤
n
≤
255
(even number)
48
≤
d
≤
57
71
CODABAR
1
≤
n
≤
255
48
≤
d
≤
57, 65
≤
d
≤
68,
36,43,45,46,47,58
72
CODE93
1
≤
n
≤
255
0
≤
d
≤
127
℃
73 CODE128
2
≤
n
≤
255
0
≤
d
≤
127
[Details for℃]
This command ends with a NUL code.
When the bar code system used is UPC-A or UPC-E, the printer prints the bar code data after
receiving 12 bytes bar code data and processes the following data as normal data.
When the bar code system used is JAN 13, the printer prints the bar code after receiving 13
bytes bar code data and processes the following date as normal data.
When the bar code system used is JAN 8, the printer prints the bar code after receiving 8 bytes
bar code data and processes the following data as normal data.
The number of data for ITF bar code must be even numbers.
When an odd number of data is input, the printer ignores the last received data.
[Details for℃]
n
indicates the number of bar code data, and the printer processes n bytes from the next
character data as bar code data.
If
n
is outside of the specified range the printer stops command processing and processes the
following data as normal data.
[Details in standard made]
If
d
is outside of the specified range, the printer only feeds paper and process the following data
as normal data.
If the horizontal size exceeds printing area, the printer only feeds the paper.
This command feeds as much paper as is required to print the bar code, regardless of the line
spacing specified by
ESC 2
or
ESC 3
.
This command is enabled only when on data exists in the print buffer.
When data exists in the print butter, the printer processes the data following m as normal data.
After printing bar code, this command sets the print position to the beginning of the line.
This command is not affected by print modes (emphasized, double-strike, underline, character
size, white/black reverse printing, or 90˚ rotated character, etc), except for upside-down printing
mode.
[Details in page made] This command develops bar coed data in the print buffer, but does not print it. After processing
bar cod data, this command moves the print position to the right side dot of the bar code.
If d is out of the specified rang, the printer stops command processing and processes the
following data as normal data. In this case, the data butter position does not change.
If bar code width exceeds the printing area, the printer does not print the bar code but moves the
data buffer position to the left side out of the printing area.
Refer to Figure 3.12.3 for bar code data buffer position.
When CODE93 (m=72) is used :
The printer prints an HRI character (□)as start character at the beginning of the HRI character
string.
The printer prints an HRI character(□)as a stop character at the end of the HRI character string.
The printer HRI characters (■+an alphabetic character)
as a control character(<00>H to <1F>H and <7F>H):
Control character
HRI character
Control character
HRI character