Step 2 - Installatation of 2D sensor
Locating a suitable spot to install the 2D sensor is worthwhile taking some time to get
right.
You are looking for a place that:
Is accessible
•
The sensor is able to be reached and removed from its mount with the removal key without undue
interference.
Sensor will be level and facing forward
•
Arrows on the top of the sensor indicate it is to be installed facing toward the front of the cab.
•
The sensor ideally needs to be placed in a spot that is level to the floor of the cab.
•
Installing the 2D sensor on a tilt is acceptable if a level location is unable to be found.
•
A maximum angle of +/- 30° on both axes is ok.
Is free from vibration and strong magnetic Interference
•
Avoid plastic moulding that is removable, as this can vibrate when the machine is running.
•
Avoid being near storage of tools or devices that are strongly magnetic.
Has adequate space for cable and plug
•
The communication cable is not under tension. Use an extra XD418 cable if more length is required.
•
The cable and plug into the sensor sticks out approx. 2.5cm from edge of sensor. 5-7cm clearance is
desirable to avoid complications with the cable bending too sharply.
Will not be subject to knocks or damage
•
Avoid areas where tools are commonly stored
•
On some machines, under the floormats to the side of the operators feet is the only location. Take care
to make a safe place where the sensor and cable will not be affected.
Examples of 2D sensor installation below: